Preset Parameters
Jog Mem Addr 0500H(41281)
Range: 0.0 to 400.0 Hz Default Setting: 6.0
The Jog Command is selected by a Multi-Function Input Terminal (3-02 and 3-03) set
to the Jog Function (9).
Multi-Speed 1 Mem Addr 0501H(41282)
Multi-Speed 2 Mem Addr 0502H(41283)
Multi-Speed 3 Mem Addr 0503H(41284)
Range for 5-01 to 5-03: 0.0 to 400.0 Hz Default Setting: 0.0
•The Multi-Function Input Terminals (refer to 3-02 and 3-03) are used to select
one of the AC drive Multi-Step speeds. The speeds (frequencies) are determined
by 5-01 to 5-03 shown above.
Note: When all multi-speed inputs are off, the AC drive reverts back to the Command
Frequency (4-00).
5-03
5-02
5-01
5-00
Frequency
Time
Jog Frequency
DecelAccel
Jog Operation
Command
ON
OFF
1-02 / 1-06
1-01 / 1-05
5-00
GS1 Series AC Drive User Manual
4–37
Chapter 4: AC Drive Parameters
Multi-Speed Bits
Speed Selection
Bit 2 Bit 1
OFF OFF 4-00: Source of Frequency
OFF
ON
5-01: Multi-Speed 1
ON
OFF 5-02: Multi-Speed 2
ON ON
5-03: Multi-Speed 3

Related product manuals