Display Parameters
User Defined Display Function Mem Addr 0800H(42049)
Default Setting: 0
Settings: 0 Output Frequency (Hz)
1 Motor Speed (RPM)
2 Output Frequency x 8-01
3 Output Current (A)
4 Motor Output Current (%)
5 Output Voltage(V)
6 DC Bus Voltage (V)
9 Frequency Setpoint
Frequency Scale Factor Mem Addr 0801H(42050)
Range: 0.1 to 160.0 Default Setting: 1.0
The coefficient K determines the multiplying factor for the user-defined unit.
The display value is calculated as follows:
Display value = output frequency x K
The display window is only capable of showing four digits, but
8-01 can be used to create larger numbers. The display window uses decimal
points to signify numbers up to three digits as explained below:
DISPLAY NUMBER REPRESENTED
9999 The absence of a decimal point indicates a four digit integer.
999.9 A single decimal point between the middle and the right-most
numbers is a true decimal point; it separates ones and tenths
as in “30.5 (thirty and one-half).
9999. A single decimal point after the right-most number is not a
true decimal point; instead it indicates that a zero follows the
right-most numbers. For example, the number 1230 would be
displayed as “123.
8-01
8-00
GS1 Series AC Drive User Manual
4–45
Chapter 4: AC Drive Parameters