EasyManua.ls Logo

Autonics LE365S-41 User Manual

Autonics LE365S-41
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
K-89
Weekly/Yearly Timer
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
LE365S-41
CONTACT OUT:
250VAC 15A,
30VDC 5A
RESISTIVE LOAD
SOURCE:
100-240VAC
50/60
Hz
1 2 3 4
Ordering Information
Features
Specications
W48×H48mm, Weekly/Yearly Timer
● Easy to check and change the program setting
● Customizable weekly or yearly unit time setting and
control by user
● Includes daylight saving time function
● 1 independent control output. (relay)
● Flush and surface, DIN rail mounting are in one unit.
Connections
Model LE365S-41
Power supply 100-240VAC
50/60
Hz
Allowable voltage range 90 to 110% of rated voltage
Power consumption Max. 2.4VA (100-240VAC
)
Timing program 48 steps for weekly, 24 steps for yearly
Operation mode ON/OFF mode, cycle mode, pulse mode
Mounting Panel ush, surface, DIN rail
Time deviation ±15sec/month (ambient temperature: 25
) (±4sec/week)
Temperature error ±0.01% ±0.05sec
Memory protection Over 5 years (at 25
)
Control
Output
Contact type SPST (Single Pole Single Throw)
Contact capacity 250VAC
15A, 30VDC 5A resistive load
Output number Independent 1 output (1a)
Relay
life cycle
Mechanical Min. 5,000,000 operations (switching capacity 30 times/min)
Electrical 50,000 operations<switching capacity 20 times/min, 250VAC 15A (resistive load)>
Insulation resistance Over 100MΩ (at 500VDC megger)
Dielectric strength 2,000VAC 50/60Hz for 1minute
Noise immunity ±2kV the square wave noise (pulse width: 1μs) by the noise simulator
Environment
Ambient temperature -10 to 55
, storage: -25 to 65
Ambient humidity 35 to 85%RH
Unit weight Approx. 110g
Item
Size
Power supply
Output
LE365 S 4 1
1 1 Relay output
4 100-240VAC 50/60
Hz
S DIN W48×H48
mm
LE365 Weekly/Yearly timer
Environment resistance is rated at no freezing or condensation.
Please read “Caution for your safety” in operation
manual before using.

Other manuals for Autonics LE365S-41

Question and Answer IconNeed help?

Do you have a question about the Autonics LE365S-41 and is the answer not in the manual?

Autonics LE365S-41 Specifications

General IconGeneral
TypeDigital Timer
Mounting TypeDIN Rail Mount
Number of Digits4
Output TypeRelay
Display TypeLED
Operation ModeFlicker, One-Shot
Contact Rating5 A at 250 VAC
Operating Temperature-10°C to +50°C
Storage Temperature-20°C ~ 65°C
Protection DegreeIP40
Input Voltage100-240 VAC 50/60 Hz

Summary

Specifications

Connections

Dimensions and Mounting

Front Panel Mounting

Details for installing the timer via front panel mounting.

Surface Mounting

Details for installing the timer via surface mounting.

DIN Rail Mounting

Details for installing the timer via DIN rail mounting.

Panel Cut-out Dimensions

Specifications for the panel cut-out required for mounting.

Switching Mounting Types

Unit Description

Functions and Operation Modes

Weekly ON/OFF Mode

Details operation mode where output is controlled by ON/OFF set times.

Weekly Cycle Operation

Details operation mode that outputs ON/OFF for set time widths within a cycle.

Program Operation Modes Details

Weekly ON/OFF Mode Details

Describes the weekly ON/OFF mode with its steps and time settings.

Weekly Pulse Mode Details

Describes the weekly pulse mode with its steps and pulse width.

Yearly ON/OFF Mode Details

Describes the yearly ON/OFF mode with its start/stop dates and times.

Yearly Pulse Mode Details

Describes the yearly pulse mode with start/stop dates and pulse width.

Power Restore Mode

Season Switching Mode

Daylight Saving Time

Auto Daylight Saving Time

Configures automatic daylight saving time adjustments.

Normal Daylight Saving Time

Manual daylight saving time adjustment via button press.

Current Time Setting Procedure

Year, Month, Date Setting

Procedure to set the current year, month, and date.

AM/PM Time Setting

Procedure to set the AM/PM and hour for the current time.

Hour, Minute Time Setting

Procedure to set the hour and minute for the current time.

Program Setting Groups

Setting Group 1 Operations

Covers settings for weekly programs, including setting, deletion, and day changes.

Setting Group 2 Operations

Covers settings for yearly programs, time, power failure, and season switching.

Weekly Program Setting Examples

Weekly ON/OFF Mode Example

Illustrates setting up a weekly ON/OFF program with specific times.

Weekly Pulse Mode Example

Illustrates setting up a weekly pulse program with specific times.

Weekly Cycle Mode Example

Setting ON Day and Time

Steps for setting ON day and time for weekly cycle mode.

Setting Pulse Width

Steps for setting the pulse width in weekly pulse mode.

Setting ON/OFF Time Widths

Steps for setting ON and OFF time widths for weekly cycle mode.

Weekly Day Change Function

Weekly Day Change Example

Example of temporarily operating on a standard day's program.

Weekly Day Change Cancellation

Procedure to cancel or modify weekly day change settings.

Yearly Holiday Mode

Yearly Holiday Mode Setup

Instructions to set yearly holiday periods for output control.

Yearly Program Setting Examples

Yearly ON/OFF Mode Example

Example of setting up a yearly ON/OFF program with dates and times.

Yearly Pulse Mode Example

Example of setting up a yearly pulse program with dates and times.

Program Check, Modify And Delete

Weekly Program Check, Modify, Delete

Procedures for checking, modifying, or deleting weekly programs.

Yearly Program Check, Modify, Delete

Procedures for checking, modifying, or deleting yearly programs.

Related product manuals