N-38
LE4S Series
Proper Usage
Main circuit
(Figure 1)
< Sensor >
Power
Rectication
circuit
Isolation
transformer
<External sensor
power supply>
START
RESET
INHIBIT
● Follow instructions in 'Proper Usage'. Otherwise, it may cause unexpected accidents.
● When supplying or turning o󰀨 the power, use a switch or etc. to avoid chattering.
● Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
● In order to block peripheral current, use isolation transformer which of secondary part is not grounded as (Figure 1) to
supply power to the external input device.
● Do not connect two or more timers with only one input contact or transistor simultaneously.
● Keep away from high voltage lines or power lines to prevent inductive noise.
In case installing power line and input signal line closely, use line lter or varistor at power line and shielded wire at input
signal line.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
● This unit may be used in the following environments.
①
Indoors (in the environment condition rated in 'Specications')
②
Altitude max. 2,000m
③
Pollution degree 2
④
Installation category II