Sanitizer Output Settings and Adjustments
1.
Power up the ChlorSync
®
chlorinator.
2.
If flow is present, the salt is measured within ten (10) seconds and the salt LED is properly displayed. If
the salt level is below 2,300 ppm (mg/L), the red Salt indicator will be illuminated. The Cell light will be
blank, indicating chlorine production has stopped due to low salt conditions.
3.
Press the orbuttons to set the sanitizer output to 50%.
4.
After 24 hours, test the pool water for free available chlorine. Ideally, the free available chlorine should
be maintained at 2.0 - 4.0 ppm (mg/L). You can increase the ChlorSync
®
sanitizer output % if the free
chlorine is too low by pressing the button. To decrease the sanitizer output, press the button.
l During the first two weeks, test the water chemistry parameters every 3 - 4 days. Adjust sanitizer output
percentage as needed until the free chlorine is stabilized at 2.0 - 4.0 ppm (mg/L).
MAINTENANCE
Cleaning the Cell
Self Cleaning: Your AutoPilot
®
chlorinator is designed to automatically self-clean calcium scale
build up that may form on the blades during normal operation. However, unbalanced water
chemistry can cause a heavy scale build up exceeding self-cleaning capabilities. Periodic
manual cleaning may be necessary. The simplest way to avoid this extra work is to maintain the
water chemistry at the levels recommended.
White, flaky or crusty calcium build up on the edge or between the blades will shorten the life of
the cell. If required, clean the cell immediately and determine the cause of scaling.
A small amount of scale accumulation is normal, but if your cell shows excessive scaling on a
regular basis, it is recommended to inspect the cell every eight (8) weeks and clean as
appropriate. In areas where there is high water hardness, more frequent visual inspection and
cleaning may be needed.
WARNING - Failure to heed the following may result in permanent injury or death.
l CHEMICAL HAZARD - To avoid damaging splashes, always add acid to water, never
water to acid. Wear safety glasses and use other appropriate personal protection
equipment.
CAUTION - Failure to heed the following may result in equipment damage.
l Scraping or scratching the titanium blade’s edge or surface will damage the blade catalyst coating and
cause premature failure of the cell. The warranty will be voided. Never use any sharp or metallic objects
to remove scale.
Cell Cleaning:
ChlorSync
®
Cell Cleaning
Kit
Figure 6
1.
Turn off the water circulation pump.
2.
Power off the ChlorSync
®
power center and disconnect the cell
from the power center.
3.
Remove any loose scale with a garden hose using a high-pressure
attachment.
4.
Using AutoPilot
®
Acid Wash Kit part #STK0227, secure the acid
wash stand onto the threaded end of the ChlorSync
®
cell. Verify the
o-ring is properly seated on the stand.
5.
Fill the cell with water two inches from the top of the cell blades.

Questions and Answers: