EasyManuals Logo

AUX ASW-H18E3B4/FAR3DI-C0 User Manual

AUX ASW-H18E3B4/FAR3DI-C0
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
25
If the water drain is smooth.
If the wiring and piping are correctly installed.
Check that no foreign matter or tools are left inside the unit.
Leak test of the refrigerant
Depending on the installation method, the following methods may be used to check
for suspect leak, on areas such as the four connections of the outdoor unit and the
cores of the cut-off valves and t-valves:
Bubble method: Apply of spray a uniform layer of soap water over the suspected
leak spot and observe carefully for bubble.
Instrument method: Checking for leak by pointing the probe of the leak detector
according to the instruction to the suspect points of leak.
2. Test operation
Test preparation
Verify that all piping and connection cables are well connected.
Confirm that the values at the gas side the liquid-side are fully open.
Connect the power cord to an independent power socket.
Install batteries in remote control.
Test Operation method
Turn on the power and push the ON/OFF switch button of the remote controller to
start the air conditioner.
Select COOL, HEAT (not available on cool-only models), SWING and other
operation modes with the remote controller and see if the operation is ok.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUX ASW-H18E3B4/FAR3DI-C0 and is the answer not in the manual?

AUX ASW-H18E3B4/FAR3DI-C0 Specifications

General IconGeneral
BrandAUX
ModelASW-H18E3B4/FAR3DI-C0
CategoryAir Conditioner
LanguageEnglish

Related product manuals