18F9- outdoor EE error
Explanation of
error
Cause: Many parameters need to be preset for the running of the
Outdoor Unit of the air conditioner and such parameters are placed in a
data storage 8-feet chip, which is called "EEPROM" or "EE" for short.
The motor on the Outdoor Unit main PCB can only work after reading
the data stored in EE and if not read, the alarm "outdoor EE error"
would be reported and raised in the Indoor Unit machine. Reasons for
data not being read are as follows:
1. wrong EE chip data format;
2. EE chip is broken;
3. bad contact of EE or fault of EE reading circuit;
4. backward installation of EE chip.
Inspection path: Outdoor Unit main PCB.
Tools required
for inspection
None.
Frequent
problematic part
Bad contact of EE, Outdoor Unit main PCB.
Inspection
procedure and
key points
1. Replace the Outdoor Unit main PCB directly.