AUX air conditioner service manual
4. Heat Conductivity Factors of Several Common Used Material
Material
λkJ/m·h·
Material
λkJ/m·h·
Copper 1382 Cork 0.17-0.25
Aluminum 733 Air Interlayer 0.25
Steel 163 Water 2.1
Frosty layer 2.1 Glass 2.7-2.9
Fibre Glass 0.17-0.21 Saw Timber 0.25-0.34
Glass Cloth 0.13 Plywood 0.62-0.84
Slag Wool 0.21-0.34 Polyurethane Foam 0.042-0.11
5. Basic Property of Substitute Refrigerant
Property R-22 R-410A R-407C
R-22 R32/R125
R32/R125/
R134a
Refrigerant Composition
Mass Ratio %)
100 50/50 23/25/52
ODP 0.05 0 0 Environme
nt
Protection
GWP100Y
1730 1700 1530
Toxicity None None None
Safety
Combustibility Incombustible Incombustible Incombustible
Azeotropic Prop --- Subazeotropic Subazeotropic
Boil Temp
-40.8 -52.7 -43.7
Thermo-ph
ysical
Properties
Critical Temp
96.1 72.5 87.3
Refrigeration
PressureMpa
2.17 3.38 2.31
Evaporation
PressureMpa
0.62 1.00 0.64
Pressure Ratio 3.50 3.38 3.59
Exhaust Temp
97.2 95.1 86.7
Refrigerati
on
Properties
Slip Temp
0
0.17 以下 46
203