7
InstallingYourBeverageRefrigeratorContinued
INSTALLING:
Wheninstallingthebeveragerefrigeratorunderacounter,followtherecommendedspacingdimensionsshown.
• Toensureproperserviceaccessandventilation,allow
between2‐3inchesofclearanceatthebackasshown
inthediagram.
• Theinstallationshouldallowtheunittobepulled
forwardforservicing,
ifnecessary.
• Astandardelectricalsupply(115VAConly,60Hz),
properlygroundedinaccordancewithNational
ElectricalCodeandlocalcodesandordina ncesis
required.
IMPORTANT: Onceyouarereadytoi nstallitina
cabinetordirectly onthefloor,youmustadjustthe
feettolevel
thebeveragerefrigerator.
LEVELING:
Thebeveragerefrigeratorshouldbeinstalledonafirmandlevelsurfacethat willbeabletosupporttheentireweightof
afullyloadedunit.Itisimportantforthebeveragerefrigeratortobeleveledinordertoworkproperly.Itcanberaised
orloweredbyrotatingtheplastic
sheathsaroundeachofthefeetonthebottomofthemachine.Ifyoufindthatthe
surfaceisnotlevel,rotatethefeetun tilthebeveragerefrigeratorbecomeslevel.Youmayneedtomakeseveral
adjustmentstolevelit.Werecommendusingacarpenter’sleveltocheckthemachine.
Turnthelevelingfeettothe
righttolowerthatsideoftherefrigerator.Turnthelevelingfeet tothelefttoraisethatsideoftherefrigerator.
RECOMMENDEDGROUNDINGMETHOD:
Foryourpersonalsafety,thisappliancemustbegrounded.Itisequippedwitha powersupplycordhaving a3 ‐prong
groundingplug.Tominimizepossibleshockhazard,thecordmustbepluggedintoamating3‐pronged wallsocket,and
groundedinaccordancewiththeNationalElectricalCodeandlo cal
codesandordinances.Ifamatingwallsocketisnot
available,itisthepersonalresponsibilityofthecustomertohaveaproperlygrounded,3‐prongwallreceptacleinstalled
byaqualifiedelectrician.
ELECTRICALSHOCKHAZARD!
•Plugintoagrounded3‐prongoutlet
•Neverremovethegroundingprong
fromtheplug
•Neveruseanadaptertobypassthegroundingprong
•DONOTuseanextensioncord
•Failuretofollowtheseinstructionscanresultinfire,electricalshock,orpersonalinjury
Beforeyoumoveyourbeveragerefrigeratorintoitsfinallocation,itisimportanttomake
sureyouhavetheproper
electricalconnection.Astandardelectricalsupply(115V,60Hz),properlygroundedinaccordancewiththeNational
ElectricalCodeandlocalcodesandordina nces,is required.Itisre commendedthataseparatecircuit,servingonlyyour
beveragerefrigerator,beprovided.Usereceptaclesthatcannotbeturnedoff
byaswitchorpullchain.
Thefuse(orcircuitbreaker)sizeshouldbe15Amps.