Commercial Refrigerator
And Freezer Users Manual
- 1 -
User Manual
Refrigerator models: 178A12RHC, 178A19RHC, 178A23RHC,
178A23RGHC, 178A35RHC, 178A49RHC, 178A49RGHC
Freezer models: 178A12FHC, 178A19FHC, 178A23FHC, 178A35FHC,
178A49FHC
Please read the manual thoroughly prior to equipment set-up,
operation and maintenance.
10/2020

Questions and Answers

  • J
    John TuckerAug 15, 2025
    Why is my Avantco 178A12RHC Refrigerator cabinet temperature too warm?
    • K
      kathy91Aug 15, 2025
      If the Avantco Refrigerator's cabinet temperature is too warm, there might be several reasons: * The thermostat may be set too high; if so, set the thermostat to a lower temperature. * Airflow could be blocked; re-arrange products to allow proper airflow, ensuring at least four inches of clearance from the fan. * Low refrigerant levels might be the issue; in this case, contact a service technician to check the refrigerant levels. * The door might be slightly ajar; ensure the door is completely closed.
  • B
    Brian JohnsonAug 18, 2025
    Why is the Avantco Refrigerator cabinet temperature too warm?
    • C
      Cameron GregoryAug 18, 2025
      Several factors can cause the Avantco Refrigerator cabinet temperature to be too warm. The thermostat might be set too warm; try setting it to a lower temperature. Airflow could be blocked, so rearrange the product to allow proper airflow, ensuring at least four inches of clearance from the evaporator. An excessive amount of warm product placed in the cabinet requires adequate time to cool down. Also, check if a fuse is blown or a circuit breaker is tripped, and replace or reset it if necessary. Other potential causes include a dirty condenser coil, an evaporator coil iced over (ensure doors are closed), low refrigerant levels (contact a service technician), or a door slightly ajar (ensure it's completely closed).
  • D
    David BrownAug 21, 2025
    What to do if condensation is collecting on the Avantco 178A12RHC?
    • A
      amuellerAug 21, 2025
      If you notice condensation collecting on the cabinet or floor of your Avantco Refrigerator, it's likely that the gasket is not sealing properly. You should clean, repair, or replace the gasket as necessary.
  • D
    Donald RobinsonAug 25, 2025
    Why is condensation collecting on my Avantco Refrigerator cabinet and/or floor?
    • L
      lpittsAug 26, 2025
      Condensation on your Avantco Refrigerator cabinet or floor can occur if the gasket is not sealing properly; clean, repair, or replace it as needed. Another cause could be a relative humidity above 60%; move the unit to an area with lower relative humidity or lower the humidity level in the current area.
  • T
    Terry LyonsAug 28, 2025
    What to do if the compressor is not running on my Avantco 178A12RHC?
    • F
      frances03Aug 28, 2025
      If the compressor in your Avantco Refrigerator isn't running, here are a few things to check: * A fuse might be blown, or a circuit breaker tripped. If so, replace the fuse or reset the circuit breaker. * The power cord might be unplugged; make sure to plug it in. * The thermostat could be set too high; adjust the thermostat to a lower temperature. * The cabinet may be in a defrost cycle; wait for the defrost cycle to finish.
  • A
    amanda72Aug 31, 2025
    How to fix the interior light on my Avantco Refrigerator?
    • R
      ricekaylaAug 31, 2025
      If the interior light in your Avantco Refrigerator is not working, consider the following: * There might be a poor switch connection; try turning the light switch off and then back on. * The bulb might not be connected properly; ensure the bulb is correctly inserted in the socket. * The bulb may have burned out; replace the bulb.
  • G
    gbrownSep 3, 2025
    Why does my Avantco 178A12RHC condensing unit run for long periods of time?
    • R
      Ruth TerrellSep 3, 2025
      The condensing unit in your Avantco Refrigerator might run for extended periods due to several reasons. An excessive amount of warm product placed inside the cabinet requires adequate cooling time. Prolonged door openings or doors left ajar can also cause this issue, so ensure doors are closed when not in use and avoid opening them for long periods. Additionally, check the door gaskets to ensure they are sealing properly; snap them in completely, wash them with soap and water, and replace them if necessary. An iced-over evaporator coil might also be the cause; unplug the unit to allow the coil to defrost, ensure the thermostat isn't set too cold, and verify the door gaskets are sealing properly.
  • M
    Mary MartinSep 7, 2025
    What to do if the Avantco Refrigerator compressor is not running?
    • D
      Diana PerrySep 7, 2025
      If the compressor on your Avantco Refrigerator isn't running, first check if a fuse is blown or a circuit breaker has tripped; replace the fuse or reset the breaker if needed. Ensure the power cord is plugged in securely. Also, verify that the thermostat isn't set too high; set it to a lower temperature. Finally, the refrigerator might be in a defrost cycle, so wait for the cycle to finish.
  • L
    Leah GoodmanSep 10, 2025
    How to fix an interior light that is not working in Avantco 178A12RHC?
    • S
      Stacey LamSep 10, 2025
      If the interior light in your Avantco Refrigerator isn't working, first try turning the light switch off and then back on to address a poor switch connection. If that doesn't work, check to ensure the bulb is correctly inserted in the socket. If the bulb is properly connected, it may have burned out and need to be replaced.

Avantco 178A12RHC Specifications

General IconGeneral
Model178A12RHC
TypeReach-In Refrigerator
Number of Doors1
Temperature Range33 - 40 Degrees F
Capacity12 cu. ft.
Shelves3
Interior LightYes
Phase1
Number of Sections1
Horsepower1/5 HP
Door TypeSolid
Hertz60 Hertz
Voltage115V
RefrigerantR290
Amperage2.4 Amps