Type of AVANTI Runner:
Runner 2000/2002 or Eagle
DS
User´s name:
Standards: EN353-1 / RfU11.073 / AS/NZS1891.3 Phone:
Tower (WEA-No.): Name of inspector:
Date of inspection: Date of next inspection:
1 Ladder system OK NOK COMMENTS
1.1 Rungs Are dents less than 10 mm in diameter or 1 mm deep?
Are the rung ends xed tight to the stiles?
Are the rungs free of cracks?
1.2 Stiles Are dents less than 20 mm in diameter or 1 mm deep?
Are the stile ends free of dents?
Are the stiles free of cracks?
1.3 Flange connection kits
Is the distance between the rungs of consecutive ladder sections at tower flange between 255 and 300 mm?
1.4 Ladder ends Are the AVANTI rubber feet or end caps mounted?
1.5 General Is the ladder system free of dirt (oil, corrosion, paint, etc.)?
2 Safety rail system OK NOK COMMENTS
2.1 Safety rail sections Are the safety rail sections mounted on the front side?
Is the guide seat of each safety rail section placed on the left side?
Are the ends of each safety rail section free of sharp edges?
2.2 Rung tting Is there a rung tting on the rst (lowest) rung of each ladder section?
Is there a rung tting on the last (highest) rung of each ladder section?
Is there a rung tting on at least every third rung of each ladder section?
Is each rung tting free of damages?
2.3 Fish-joints Is each sh-joint mounted with 4 hammerhead screws?
Are all the indicator marks of the hammerhead screws and the self-locking nuts at an angle of 70º?
2.4 General Is the safety rail system free of dirt (oil, corrosion, paint, etc.)?
Is the safety rail system free of damages?
3 Others OK NOK COMMENTS
3.1 Resting platforms Are the resting platforms in place and xed properly?
3.2 Screws Are all the screws in place and torqued properly?
3.3 Labels and markings Are all the labels and markings legible?
4 Runner system OK NOK COMMENTS
4.1 - Is the runner approved for use?
5 Final assessment OK NOK COMMENTS
5.1 - Is the FPS approved for use?
This inspection shall be carried out before the rst use and at least every 12 months by AVANTI or by a
certied technician. This checklist and the Inspection log sheet shall be lled in and led for future reference.
Inspector´s Signature: