Loading...
Private VLAN Edge Technical Configuration Guide
12
July 2010
avaya.com
2.1.2 Verify Operations
2.1.2.1 Verify policy configuration
Step 1 Verify Action Extension:
4550T-1# show qos if-action-extension
Result:
Id: 1
Name: fwd_port_27
Egress Ucast Ifc: 27
Egress NUcast Ifc: 27
Session Id: 0
Storage Type: NonVolatile
Step 2 Verify Action:
4550T-1# show qos action
Result:
Id: 1
Name: Drop_Traffic
Drop: Yes
Update DSCP: Ignore
802.1p Priority: Ignore
Set Drop Precedence: High Drop
Extension:
Session Id: 0
Storage Type: ReadOnly
Id: 2
Name: Standard_Service
Drop: No
Update DSCP: 0x0
802.1p Priority: Priority 0
Set Drop Precedence: High Drop
Extension:
Session Id: 0
Storage Type: ReadOnly
|
|

Other manuals for Avaya 4500