Private VLAN Edge Technical Configuration Guide
Id: 10
Name: fwd_27
Drop: No
Update DSCP: Ignore
802.1p Priority: Ignore
Set Drop Precedence: Low Drop
Extension: fwd_port_27
Session Id: 0
Storage Type: NonVolatile
Step 1 – Verify QoS Policy:
Id: 1
Policy Name: fwd_port_27
State: Enabled
Classifier Type: Classifier
Classifier Name: all_traffic
Classifier Id: 1
Role Combination: pri_vlan
Meter:
Meter Id:
In-Profile Action: fwd_27
In-Profile Action Id: 10
Non-Match Action:
Non-Match Action Id:
Track Statistics: No
Precedence: 10
Version: Version 1
Session Id: 0
Storage Type: NonVolatile
Verify the following information:
if-action-extension 1:
Name
Egress Ucast Ifc
Egress NUcast Ifc
Displays the egress port used by the action extension, ID = 1 using a name of
fwd_port_27, where Egress Icast Ifc and Egress NUcast Ifc should both display
27. Port 27, as used by for this example, is used as the unicast and non-unicast
forwarding port.