Environmental component Specification for ERS 3500 series
Maximum Operating Altitude 10,000 ft
Storage Altitude 10,000 ft
Acoustic Noise (db) ERS3650GTS — 40.7dB@25C, 47.4dB@50C
ERS3650GTS-PWR+ — 46.8dB@25C, 54.6dB@50C
ERS3626GTS — 41.2dB@25C, 49.3dB@50C
ERS3626GTS-PWR+ — 44.6dB@25C, 54.5dB@50C
Miscellaneous Operating Considerations • At least 5cm (2") on each side of the switch unit for
ventilation
• Adequate power source within six feet. One 15 amp
circuit required for each power supply
• No excessive dust
• No nearby sources of severe electromagnetic noise
• No nearby heat sources such as hot air vents or
direct sunlight
Power specifications
This section provides the following specifications for Avaya Ethernet Routing Switch 3600 Series.
Table 4: AC power specifications
Model
Power supply Input power (margined by
10%)
Power consumption
(Thermal rating)
Rated Line
voltage
Watts
(Total)
Amps Watts BTUs/
hour
ERS3626GTS 54W 100V-110V
AC
24.60 0.42 24.60 83.94
54W 200-240VA
C
24.78 0.24 24.78 84.55
ERS3626GTS-PWR+ 914.1W 100V-110V
AC
874.92 7.05 151.90 518.35
54W 200-240VA
C
828.69 3.66 105.70 360.61
ERS3650GTS 54W 100V-240V
AC
41.77 0.69 41.77 142.52
54W 200-240VA
C
41.54 0.41 41.54 141.73
Table continues…
Installation preparation
January 2017 Installing Avaya Ethernet Routing Switch 3600 Series 14
Comments on this document? infodev@avaya.com