AXISA1610NetworkDoorController
DonotconnecttheAxisproducttoareceptaclecontrolledbyaswitch.
Battery
-The3.0VlithiumbatteryusedbytheAxisproductisaULrecognized
component.(Type:BR2032,diameter:20mm(0.78in),manufacturers:
PowerGlory(Omnergy)).ThefollowingbatterytypeisalsoaULrecognized
component:TypeCR2032.
-Usersshallnotreplacethebattery.Ifthebatteryneedsreplacing,itmust
bedonebyatrainedtechnicianonly.
-Usedbatteriesshallbedisposedofaccordingtolocallawsandregulations,
whichmayvaryfromstatetostate.WasteBR/CRlithiumcellsareneither
listednorexemptedfromtheUSEPAhazardouswasteregulations.Waste
lithiumbatteriescanbeconsideredreactivehazardouswasteifthereisa
signicantamountofunreacted,orunconsumedlithiumremaining.For
informationabouthowtodisposeofusedlithiumbatteries,contactyourlocal
authorityforwastedisposal.
Specications
Operatingconditions
Normaluse(notevaluatedbyUL)-40°Cto55°C(-40°Fto131°F)
Humidity20–85%RH(non-condensing)
UL294
0°Cto55°C(32°Fto131°F),maximum
humidity85%.
Wiringrequirements
-ULlistedorR/CAWMwiresthathaveaconductorgaugerangeof
AWG22–14shallbeused.
-Theminimumconductorgaugeforconnectionbetweenthepowersourcing
equipment(PSE)orpowerinjectorandthepowereddevice(PD)is26AWG.
-MinimumPoEcategory5e,shieldedcable,requiredforPoE.
-ThisproductisnotintendedforoutsidewiringascoveredbyArticle800inthe
NationalElectricalCode,NFPA70.
Connectors
-PowerConnectorForULsecurityapplications,theproductshallbepowered
byaUL294orUL603listedClass2low-voltagepowerSELVandlimited
powersupplywithappropriateratings.
-Externalpowertorelays-Iftherelaysareconnectedtoanexternalpower
sourcethismustbeUL294listedClass2low-voltagepowerSELVandlimited
powersupply.