RequirementsforcompliancewithUL294
ThissectioncontainsinformationandinstructionsrequiredforULcompliance.Tomakesurethe
installationisULcompliant,followtheinstructionsbelowinadditiontothegeneralinformation
andinstructionsprovidedthroughoutthisdocument.Incaseswherepiecesofinformation
contradicteachother,therequirementsforULcompliancealwaysreplacegeneralinformation
andinstructions.
Performancelevelsforaccesscontrol
ThissectioncontainsperformancelevelinformationrequiredforUL294compliance.
FeatureLevel
DestructiveattacktestI
Security
I
EnduranceIV
Standbypower
I
Supportedreaders
•ForUL294,compatibilitywiththefollowingreadershasbeenveriedbyUL:
AXISA4020-E,AXISA4120–EandHIDSigno20.
Safetyinstructions
•ShallbeinstalledinaccordancewithArticle725.121oftheNationalElectricalCode,
ANSI/NFPA70.
•TheAxisproductshallbeinstalledandservicedbyafactorytrainedprofessional.
•TheAxisproductshallbeinstalledwithintheprotectedpremises(securedarea).
•TheAxisproductshallbemountedindoors.Outdoorusehasnotbeenevaluatedor
approvedbyUL.
•AllinterconnectingdevicesshallbeULlistedandClass2low-voltagepowerlimited.
•AllpoweroutputsareClass2outputs.
•AllwiringmethodsshallbeperformedinaccordancewithANSI/NFPA70,localcodesand
authoritieshavingjurisdiction.
•RecommendtouseULrecognizedgroundingwire,asizeof14-16AWG,yellow/green
color.Crimpthecableonthenon-insulatedwirepressureringterminalwhichisbeing
deliveredasasparepartoftheproduct.Importanttousepropercrimpingtooland
techniquestoensurethesafetyofproductanduser.
•WhentheAxisproducthasreachedtheendofitsusefullife,disposeofitaccording
tolocallawsandregulations.Theproductshouldnotbedisposedoftogetherwith
householdorcommercialwaste.SeeDisposalandrecyclingonpage3.