AXISA4011-EReader
WireArea
NO NO
NO
TICE TICE
TICE
Eachwireshallhaveanareathatcorrespondstoanconductorgaugerangeof
AWG28–16(CSA)orAWG22–14(cUL/UL).Selectcablesincompliancewithyourlocal
regulations.
AWG
Diametermm(in)
Areamm
2
28–16
0.321–1.29(0.0126–0.0508)
0.0810–1.31
22–14
0.644–1.63(0.0253–0.0641)
0.326–2.08
TamperingAlarm
Thetamperingalarmswitchandtamperingalarmsensorcantogglebetweenanopenandclosed
circuit.Whenthereaderisremovedfromthesurfaceitisattachedto,orwhenthefrontplateis
removed,analarmeventissenttothedoorcontroller.Inthedoorcontroller,thealarmeventcan
beusedtotriggeranaction.Forinformation,seethedoorcontroller’sUserManual.
DIPSwitches
ThereadercanbeconguredthrougheightDIPswitchesthatarelocatedontherightsideofthe
circuitboard.Tochangetheconguration,removethefrontplate,andtheniptheDIPswitches
asrequired.Forinformationaboutcardformatsandreaderfeedback,seethedoorcontroller’s
UserManual.
DIPDefaultsettingFunction
1
OFF
Addressvalue1
2
OFF
Addressvalue2
3
OFF
Addressvalue4
4
OFF
Keybeep:beepatkeystrokesandmajor/minorsignal
atinvalid/validcard
5
OFFCardbeep:beepatcardread
6
OFF
n/a
7
OFF
Lighton:keypadalwayslit
8
OFF
Lightcode:keypadlitswhentheindicationforPINcode
isactivated
9