AXISA9188NetworkI/ORelayModule
IfthenetworkI/Omoduleisnotbehavingasexpected,seetheUsermanualfor
informationabouttroubleshootingandtheproduct’sbuilt-inmaintenancefunctions.
Forinformationaboutmaintenanceofthebattery,seeBatteryonpage6.
Specications
OperatingConditions
TheAxisproductisintendedforindooruse.
Classication
TemperatureHumidity
IEC60721-4-3Class3M3–30°Cto55°C
(–30°Fto131°F)
20–80%RH(non-condensing)
PowerConsumption
NO NO
NO
TICE TICE
TICE
UseaSafetyExtraLowVoltage(SELV)compliantlimitedpowersource(LPS)witheithera
ratedoutputpowerlimitedto100Woraratedoutputcurrentlimitedto5A.
PowersupplyMaximumloadonoutputs
PoweroverEthernetIEEE802.3afType1Class3/
IEEE802.3atType2Class4,44–57VDC
PoEClass3:3.6W
PoEClass4:12W
8–28VDC,max26W
12W
PowerOutputConversion(WtoA)
ThetotalmaximumoutputloadoftheAxisproductdependsonthepowersource.
ThevoltageontheAxisproduct’spoweroutputsis12VDCor24VDC.Themaximumloadisthe
combinedpowerfrom12Vand24V.Forexampleifyoutake1Afrom12Voutputnopoweris
availablefrom24V.
Ifyourconnecteddevicehasamaximumampereratingofforexample0.3A,thefollowing
conversiongivesthepowerinwatts(W):
Power(W)=Voltage(V)xCurrent(I)
Power=12Vx0.3A=3.6W
21