AXISCameraStationS22ApplianceSeries
Managethebuilt-inswitch
Thepowerrequestedismanuallyadjustedto20WforPoEclass4devices.Theswitchcanpower5PoEclass4devicesand3PoEclass
2devices.Thetotalpowerrequestedis(5x20)+(3x7)=121W.Theactualpowerconsumedis(5x15)+(3x5)=90W.Inthis
way,allconnecteddevicesareguaranteedenoughpowerandthepriorityislessimportant.
Settings
Congurenetworksettings
Youcanchangetheswitch’sIPaddress.Butformostcamerainstallations,werecommendusingthedefaultsettings.Thereasonfor
thisisthatasurveillancenetworkisnormallyisolatedfromothernetworks,forexampleacorporateLAN.Inthiscase,youwould
onlyusethesurveillancenetworktomanageandcollectsurveillancedevicesanddatafromthevideomanagementsoftware
installedontheserver.
1.Intheswitch’smanagementpage,gotoSettings>Networksettings.
2.Entertheconnectiontype,IPaddress,subnetmask,gateway,DNS1,DNS2,andhostname.
Note
Thefactorydefaultsettingsare:astaticIPconnectionwithaddress192.168.0.1andasubnetmaskwithaddress
255.255.255.0.
3.ClickSave.
Conguredateandtime
1.Intheswitch’smanagementpage,gotoSettings>Dateandtime.
2.Selectthecountryandtimezone.
3.Tosetthetimemanually,selectManualandmanuallyadjustthetime.
4.TosetupanNTPserver,selectNTPserverandentertheNTPserveraddress.
Note
NTPonlyworkswhentheswitchisconnectedtoanetworkandconguredwithInternetaccess.