AXISP1468-XLEExplosion-ProtectedBulletCamera
(
)
Versionhistory
VersionDateDetails
1.02022-12-15
Firstrelease
2.02023-10-10
Updatedmarkingdetails
3.02024-02-01
Addedcableglandinstallation
details
Specicconditionsofuse
WARNING
Alwaysrefertotheproductcerticatesforanyspecicconditionsofuse.
Takeprecautionstominimisetheriskofelectrostaticcharging.Formoreinformation,
seeMaintenanceonpage9.
Theequipmentshallonlybeusedinanareaofatleastpollutiondegree2,asdenedin
IEC60664-1.
Equipmentmustnotbeexposedtoimpactenergyexceeding2Joulestothewindow,and
4Joulestotherestofthebody.
Orientationoftheproductmustbeinaccordancewiththeinstallationinstructions.The
devicemustnotbesurroundedwithmoredustthanthesurfacescanretain.
Capacitanceofaccessiblemetalpartsoftheequipmentis85.4pFandshallbeconsidered
inthespecicapplication.
Installation
WARNING
Allinstallationandmaintenancemustbecarriedoutbyasuitablyskilledelectrician
inaccordancewithalllocalandnationalstandardsandcodesofpracticee.g.NFPA70
(NationalElectricalCode),CSAC22.1(CanadianElectricalCode,PartISafetyStandardfor
ElectricalInstallations),IEC/EN60079-14(Explosiveatmospheres-Electricalinstallations
design,selectionanderection)andIEC/EN60079-17(Explosiveatmospheres.Electrical
installationsinspectionandmaintenance).
Theinstallermustcomplywiththetechnicaldataattached.
Ensurethatallitemsareapprovedandcertiedfortheenvironmentalandinstallation
requirements.Checktheratinglabeltoensurethatthedeviceisbeingusedwithin
thecorrectambienttemperatureandenvironmentalconditions,andthatthepower
supplyissuitable.
Thedevicemustbeinstalled≤2000mabovesealevel.
Cableentrypointscanreachatemperatureof81.1°C.Useasuitablecablefortheend
application.