AXISP1468-XLEExplosion-ProtectedBulletCamera
(防 防
防
爆 爆
爆
型 型
型
弾 弾
弾
丸 丸
丸
カ カ
カ
メ メ
メ
ラ ラ
ラ
)
IECExcerticatenumberIECExBVS17.0101X
DegreeofprotectionaccordingtoEN/IEC
60529
IP66/IP68(10bar,30min)*
Operatingtemperature-40°Cto+85°C
MaterialNickelplatedbrass
NitrilerubberNBR
Cablediameter
8–13mm
Specicconditionsofusetobeconsideredfor
installationwiththisdevice
Thecableglandistestedwithareducedtensile
force(25%)inaccordancewithclauseA.3.1
ofIEC60079-0.Itmayonlybeusedforxed
installationofGroupIIandGroupIIIapparatus.
Theusershallensureadequateclampingof
thecable.
*TheIngressProtectionofthedeviceisnotrelyingonthecablegland.Insteaditisprovided
bythecablegrommetsinsidetheequipment.
Cableglandinstallation
WARNING
Hazardduetomodicationoralteration!Explosionprotectionatrisk!
Thecableglandmaynotbemodiedoraltered.
Beforeinstallation:
•Ensurethatthecableglandisundamaged.Checkthethread,sealingringsand
o-ring-sealings.
•Removethedustcap.
•Additionalreliablestrainrelief/anchoragemustbeguaranteedfortheinsertedand
xedinstalledcables.
Duringinstallation:
•Makesurethatthecableglandisfullyscrewedintotheconnectingthread.
•Ensureproperseatingofthesealingringsando-ring-sealings.
•Ensurethatthespeciedprotectiongradesareupheld.
•Topreventloosening,ifnecessaryuseanadditionalhexagonallocknutorsuitablethread
lockinguid.
8