During level-sensitive operation, applying a voltage to the
trigger input will set the amplifier to the “Operate” mode.
When the applied voltage drops to zero, the unit reverts to
“Standby”.
In the pulse-sensitive mode, a positive-going pulse will toggle
the amplifier between the “Standby” and “Operate” states,
duplicating the action of the front-panel button.
The front-panel button remains operative when
the trigger input is used. Therefore, using the
front-panel button will put the amplifier out of
“sync” with the trigger control device. When used
with level-sensitive trigger operation, the next
trigger action will automatically restore “sync”.
However when using pulse-sensitive trigger
operation, “sync” can only be restored by pressing
the front-panel button a second time.