TEST ADJUST FINISH
Insert probe at the appropriate sampling point based on equipment type (be sure to avoid
diluon of the gas sample)
Review all combuson data from
various sources:
• Hold Screen
• Data previously saved to memory
(oponal)
• Printout (oponal)
Allow instrument to purge aer a
test
Start (RUN) and Stop (HOLD) Test
Forced Air Furnace Hot Water Tank Condensing Furnace
or Boiler
Fan Assist or
Power Vented
Furnace or Boiler
Boiler
O
2
, CO, Stack Temp
Undiluted
Flue Gas
O
2
, CO, Stack Temp Combuson Air O
2
, CO, Stack Temp O
2
, CO, Stack TempO
2
, CO, Stack Temp
Print data (F1 buon) and/or Save data
(F3 buon) to memory if desired
Run Nat Gas
T-STK 374 °F
T-Air 68 °F
EA 44.8 %
CO(0) 116 ppm
Run Nat Gas
O
2
7.0 %
CO 107 ppm
Eff 80.9 %
CO
2
7.9 %
Toggle
Between
Run and
Hold Modes
Scroll Bar
Indicates
More Items
Print
Screen
Display
Main
Menu
Save Results
to Memory
161
8 to 16 in.
(20 to 41 cm)
Made in USA
IrDA
Printer
Adjust combuson equipment as
needed based on combuson data
and manufacturer recommendaons
for the combuson device under test
Retest combuson device to verify
proper/opmal operaon
Hold Nat Gas
O
2
7.0 %
CO 107 ppm
Eff 80.9 %
CO
2
7.9 %
BACHARACH, Inc.
InTech
SN: AB1234
Time: 12:25:41
Date: 02/8/16
Fuel
NGAS
O 7.0 %
CO 107 ppm
Lambda 1.5
CO 7.8 %
CO Max 11.8 %
T-STK 190 C
T-AIR 20.0 C
qA 9.5 %
Eta 90.5 %
Eff 80.9 %
CO/CO2 0.0014
CO(O) 161 ppm
AVG SMOKE ***
OIL DERIV ***
BOILER TEMP *** C
=========================
-------------------------
Comments:
2
2
O
O
2
O
Bridge Street HVAC
Outer Kensington West
London,ENG SW1J 3
RE-TEST
BACHARACH, Inc.
InTech
SN: AB1234
Time: 12:25:41
Date: 02/8/16
Fuel
NGAS
O 7.0 %
CO 107 ppm
Lambda 1.5
CO 7.8 %
CO Max 11.8 %
T-STK 190 C
T-AIR 20.0 C
qA 9.5 %
Eta 90.5 %
Eff 80.9 %
CO/CO2 0.0014
CO(O) 161 ppm
AVG SMOKE ***
OIL DERIV ***
BOILER TEMP *** C
=========================
-------------------------
Comments:
2
2
O
O
2
O
Bridge Street HVAC
Outer Kensington West
London,ENG SW1J 3
Turn off instrument (hold PWR key)
Disconnect probe
Clean then store the instrument and
probe.
Right Arrow
Displays QR
Code for
Reporng App
Up and Down Arrows
Scroll Display
(North
American
Version Only)
(Sample Printout
from Siegert Version)