ELECTRICAL CHECKING
PROCEDURES
Pulsar 150/180 DTS-i
Service Station Manual
221
Dealer Development Center
Akurdi Pune
Measuring & Testing Equipment : Multimeter
Starter Relay Coil Resistance Checking
200 Ohms
Meter Range
3.9 Ohms 10%+
Starter Relay
Coil Red -
Yellow Wire
Meter +ve
Connections
Starter
Relay Coil
Black Wire
Meter -ve
Standard Value
SOP :
Switch OFF engine.
Connect multimeter to Starter Relay coil terminals.
Check resistance.
Disconnect coupler from Relay.
Measuring & Testing Equipment : Multimeter
Starter Relay Continuity Checking
SOP :
Connect external 12V DC supply to starter relay coil terminals.
‘Tuk’ sound will be heard.
Set multimeter on continuity mode.
Connect multimeter at to relay contact terminals.
Continuity (beep sound) indicates starter relay is OK.