ELECTRICAL CHECKING
PROCEDURES
Pulsar 150/180 DTS-i
Service Station Manual
221
Dealer Development Center
Akurdi Pune
Measuring & Testing Equipment : Multimeter
Starter Relay Coil Resistance Checking
200 Ohms
Meter Range
3.9 Ohms 10%+
Starter Relay
Coil Red -
Yellow Wire
Meter +ve
Connections
Starter
Relay Coil
Black Wire
Meter -ve
Standard Value
SOP :
• Switch OFF engine.
• Connect multimeter to Starter Relay coil terminals.
• Check resistance.
• Disconnect coupler from Relay.
Measuring & Testing Equipment : Multimeter
Starter Relay Continuity Checking
SOP :
• Connect external 12V DC supply to starter relay coil terminals.
• ‘Tuk’ sound will be heard.
• Set multimeter on continuity mode.
• Connect multimeter at to relay contact terminals.
• Continuity (beep sound) indicates starter relay is OK.