• Voltage indication and green & yellow LED's are glowing-Battery is partially
charged. Charge the battery using Metafab make VRLA battery charger
• Voltage Indication & yellow LED is glowing-Battery is discharged. Charge
the battery using Metafab make VRLA battery charger
• Voltage indication & red LED is glowing-Battery is deep discharged.
Charge battery on Metafab VRLA battery charger for 30 minutes. If battery
can not be charged, BAD battery indication will be displayed on charger &
battery needs to be disposed off, If no such indication is displayed then
continue charging till charging is over.
Pulsar 150/180 DTS-i
Service Station Manual
236
Dealer Development Center
Akurdi Pune
SOP FOR CHECKING CHARGE CONDITION OF BATTERY