EasyManua.ls Logo

Baker Hughes Panametrics dew.IQ User Manual

Baker Hughes Panametrics dew.IQ
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
dew.IQ
Moisture analyzer
User’s manual
910-295 Rev. C

Table of Contents

Questions and Answers:

Baker Hughes Panametrics dew.IQ Specifications

General IconGeneral
BrandBaker Hughes
ModelPanametrics dew.IQ
CategoryMeasuring Instruments
LanguageEnglish

Summary

Chapter 1. Features and Capabilities

1.1 Introduction

Overview of the dew.IQ analyzer and its primary functions.

1.2 Electronics

Details on the dew.IQ's electronic components and programming interface.

1.3 Probes

Information about compatible moisture probes (M Series and IQ.probe).

Chapter 2. Installation

2.2 Selecting the Analog Recorder Output

How to set the analog output to current or voltage.

2.3 Mounting the Electronics

Various mounting configurations for the dew.IQ unit.

2.5 Installing the Probe

Steps for correctly installing the moisture probe.

2.6 Wiring the System

Connecting all system components, including probes, alarms, and power.

Chapter 3. Initial Setup and Operation

3.1 Using the dew.IQ

Navigating the front panel keypad and display.

3.2 Setting Up the Display

Configuring display units, decimal places, and contrast.

3.3 Setting Up the Analog Output

Configuring the analog output signal parameters.

3.4 Setting Up Measurement Alarms

Configuring alarm thresholds, status, and types.

3.5 Viewing System Information

Accessing device status, ID, and software version.

3.6 Locking the Main Menu

Securing settings by locking the main menu.

Chapter 4. Data Logging

4.1 Checking Data Log Status

Monitoring the status of data logging operations.

4.3 Setting Log Units

Defining units for logged data.

4.4 Setting the Log Interval

Configuring the frequency of data logging.

4.7 Managing Log Files

Procedures for creating, pausing, and deleting log files.

4.8 Ejecting the MicroSD Card

Steps for safely ejecting the MicroSD card.

Chapter 5. Programming the Settings Menu

5.1 Entering Your Passcode

Procedure for accessing protected settings.

5.4 Entering Calibration Data for M Series Probe

Inputting calibration points and values for M Series probes.

5.5 Viewing Calibration Data for IQ.probe

Accessing calibration data for IQ probes.

5.6 Reading and Setting Calibration References

Adjusting high and low calibration reference points.

5.10 Selecting the Probe Type

Choosing the correct probe type for the unit.

Chapter 6. Service and Maintenance

6.3 Troubleshooting Common Problems

Guide to diagnosing and resolving common issues.

6.4 Replacing/Recalibrating Moisture Probes

Procedures for probe maintenance and calibration.

6.5 Cleaning the dew.IQ Front Panel

Instructions for cleaning the device's front panel.

Chapter 7. Specifications

7.1 Electronics

Technical specifications related to the dew.IQ electronics.

7.2 Moisture Measurement

Specifications for the moisture measurement capabilities.

Appendix A. Outline and Installation Drawings

A.1 Wall Mount Outline & Installation

Installation drawings for wall-mounted dew.IQ units.

A.2 Rack Mount Outline & Installation

Installation drawings for rack-mounted dew.IQ units.

A.3 Panel Mount Outline & Installation

Installation drawings for panel-mounted dew.IQ units.

Appendix B. Menu Maps

B.1 Main Menu Map Using M Series Probe

Graphical overview of the M Series probe menu structure.

B.2 Main Menu Map Using IQ.probe

Graphical overview of the IQ.probe menu structure.

Appendix C. Reading the MicroSD Card

C.1 Removing the MicroSD Card

Steps for safely ejecting and removing the SD card.

C.3 Accessing the Log Files

Steps for locating and opening logged data files.

C.4 Setting Up a Log File

Importing logged data into spreadsheet software.

Customer Support Centers

Americas

Contact information for technical support in the Americas.

Europe

Contact information for technical support in Europe.

Related product manuals