Template 40941_J 04-02-10 56281/56282/56283_97_A 02-01-13
4
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
Power Requirements:
Single Service [3 wires (line, neutral, ground)]
230VAC, 50Hz, 1þ, 32A, (Circuit Breaker rating = 40A max.)
System Ouputs - 32A Service:
Pump 1 230VAC 2-Speed 12A max 30-minute timer for Low Speed, 15 Minutes for High Speed
This is the heater pump
Must deliver a minimum of 20 GPM through heater
Pump 2 230VAC 1-Speed 12A max 15-minute timer
Ozone 230VAC .5A max Uses the same relay as Pump 1 Low
Spa Light 10VAC On/Off 1A max 4-Hour timer.
Heater 3kW @ 240VAC
Misc. J2 & J32 230VAC 4A max Hot output (Stereo). Fused equipment or in-line fuse required.
Wiring Diagram and Settings
Setup 1-32
J15: SPA LIGHT
BELEUCHTUNG
ECLAIRAGE BAIN HYDRO
10VAC 1A
WS01CE
FOR SUPPLY CONNECTIONS,
USE CONDUCTORS SIZED ON THE
BASIS OF 60°C AMPACITY BUT
RATED MINIMUM OF 90°C.
TORQUE RANGE FOR MAIN TERMINAL BLOCK (TB1):
27-30 IN. LBS. (31.1-34.5 kg cm)
USE COPPER CONDUCTORS ONLY
EMPLOYER UNIQUEMENT
DES CONDUCTEURS DE CUIVRE.
L2
L1
N
F3 10A 250V
F2 3A 250V
T 150mA 250V
F6
J44
J48
J1
J2
J24
J45
J49
J15
J16
J47
J13
J27
J25
J26
J23
J33
J28
J30
J31
J32
J29
J12
J46
J20
J57
J8 J14
J22
J21
J56
F5 T 30A
GND
K3
K5
K6
K2
K1
K4
OZONE
22117_B
RED AC
GND
GND
WHT AC
HTR A
HTR B
UNFUSED
CONTROL PANEL
TO J33
AUX
TO J5
S1
J45
J46
F4 3A 250V
J18 J19
K7
T1
J15
J33
J31 HCE
J30 TST
J27
H3
J22
J26 H2
J25 H1
J17
J16
J29 VAC
J28 AUX FRZ
J5
LIGHT
ON
22121_E
1
6
ALL UNUSED SWITCHES SHOULD BE OFF
STORE SETTINGS*
SPECIAL AMPERAGE RULE OFF
DON’T ADD 4 HS PUMPS W/HTR
DON’T ADD 2 HS PUMPS W/HTR
DON’T ADD 1 HS PUMP W/HTR
TEST MODE OFF
MEMORY RESET*
SPECIAL AMPERAGE RULE ON
ADD 4 HS PUMPS WITH HEAT
ADD 2 HS PUMPS WITH HEAT
ADD 1 HS PUMP WITH HEAT
TEST MODE ON
6
5
4
3
2
1
ON POSITION S1 SWITCH # OFF POSITION
*SWITCH # 6 SHOULD BE SET TO OFF
UPON FINAL INSTALLATION.
SENSOR A
SENSOR B
NOT USED
2S PUMP 1
1S PUMP 2
GRN
3.0 kW
HEATER
HEIZELEMENT
RADIATEUR
N
L1
N/A
ADDED JUMPER FOR
CE INSTALLATIONS
BLU
BRN
Confi guration Changes based on Default
Feature Orig. Setup 1 Changes to
J2 & J32 . . . . . . . . . . . . . . . . . . . . . . . Hot Output . . . . . . . . . . .Useable
DIP Switch Option Orig. Setup 1 Changes to
Add 1 High Speed Pump with Heat . . . . . . DIP Switch 2 OFF . . . . . . .DIP Switch 2 ON

Related product manuals