Action Required
The Control Panel will be disabled until power returns.
Time of day will be preserved for 30 days with a battery backup.
DO NOT ENTER THE WATER. Remove the Spa Cover and allow
water to cool. Once the Heater has cooled, reset by pushing any
button. If Spa does not reset, shut off the power to the Spa and call
your Dealer or Service Organization.
DO NOT ENTER THE WATER. Remove the Spa cover and allow
water to cool. At 43°C, the Spa should automatically reset. If Spa
does not reset, shut off power to the Spa and call your
Dealer or Service Organization.
No action required. The pump and Blower will automatically
activate regardless of Spa status.
If the problem persists, contact your Dealer or Service Organization
(May appear temporarily in an overheat situation and disappear
when the heater cools). If the problem persists, contact your Dealer
or Service Organization. (May appear temporarily in an overheat
situation and disappear when the heater cools).
If the problem persists, contact your Dealer or Service Organization.
correct, make sure the pumps have been primed. If problem persists,
contact your Dealer or Service Organization.
Follow action required for ‘HFL’ message. Heating capacity of the
Spa will not reset automatically; you may press any button to reset.
to be purged.
correct, make sure the pumps have been primed. Press any button
to reset.
Follow action required for ‘DR’ message. Spa will automatically reset;
you may press any button to reset. Potential airlock, pumps may
need to be purged.
Priming Mode will last for up to 4 minutes and then the Spa will begin
to heat and maintain the water temperature in the Standard Mode.
Meaning
No message on display.
Power has been cut off to the Spa.
‘Overheat’ - The Spa has shut down. One of the sensors has
detected (approximately 47.8°C) at the Heater.
‘Overheat’ - The Spa has shut down. One of the sensors has
detected that the Spa water is (approximately 43.3°C).
‘Ice’ - Potential freeze condition detected.
Spa is shut down. The sensor that is plugged into the Sensor ‘A’ jack
is not working.
Spa is shut down. The sensor that is plugged into the Sensor ‘B’ jack
is not working.
Sensors are out of balance. If this is alternating with the temperature,
it may just be a temporary condition. If the display shows only this
message (periodically blinking), the Spa is shut down.
A substantial difference between the temperature sensors was
‘HFL’ message within 24 hours.) Heater is shut down, but other Spa
functions continue to run normally.
Inadequate water detected in Heater.
Inadequate water detected in heater (Displays on third occurance of
‘DR’ message.) Spa is shut down.
DIAGNOSTIC MESSAGES
Message
OHH
OHS
ICE
SNA
SNB
SNS
HFL
LF
DR
DRY
PR
VL801D Quick Reference Guide