14 english
6.1 Startup
DANGER
Uncontrolled system movement
When starting up, if the sensor is part of a closed loop
system whose parameters have not yet been set, the
system may perform uncontrolled movements. This
could result in personal injury and equipment damage.
Persons must keep away from the system’s
hazardous zones.
Startup must be performed only by trained technical
personnel.
Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
and readjust the BTL if necessary. Check the values
over the entire measuring range.
Check for the correct values, especially after
replacing the BTL or after repair by the
manufacturer.
6
Startup and operation
BTL PF _ 400- _ _ _ _ -C15A _ _ _ _ - _ _ _ _ _ _
Magnetostrictive Linear Position Sensor – Profile Style