3 MAINTENANCE
3.1 ANNUAL MAINTENANCE
The appliance must be checked and cleaned annually by an authorised engineer.
This also applies to the chimney.
The annual maintenance consists of the following points:
l Cleaning the main burner, pilot light and chimney liner(s)l/combustion air
supply.
l Removing dust deposits using a vacuum cleaner.
l Checking the gas, flue and combustion air supply route for leaks.
l Checking the correct operation of the gas regulating block, thermocouple
circuit and the ignition of the main burner.
l Checking the operation of the security system.
4. FAULTS
Possible reasons for the gas fire going out are:
Operation of the security system due to flue gas escape.
Malfunction of the security system. Check by means of testing.
l Insufficient gas pressure.
l The pilot light is either dirty or defective.
l Thermocouple voltage is too low. This is usually caused by insufficient heating
at the tip of the thermocouple by the pilot light.
l Dirty electrical contacts in the thermo-electrical system; for example, the
thermocouple connection, T.T.B. wiring and/or connections of the security
system.