Instructions for physically installing the controller unit in its designated location.
Details about the standard and optional temperature sensors used with the controller.
Specifies the terminal connections for the MC4002 controller's inputs and outputs.
Lists inputs and outputs for the MC4002-A alarm board.
Lists additional outputs for the MC4002-B alarm board.
Explains the function of each button on the MC4002 controller's front panel.
Details how to implement dehumidification using a humidistat and synchronized operation.
Sequence for cooling operation with 1-stage compressors and no economizer.
Sequence for cooling operation with 2-stage compressors and no economizer.
Cooling sequences for non-alternating 2-stage units without economizers.
Cooling sequences for non-alternating 1-stage units with EIFM economizers.
Heating sequence for units with electric heat.
Heating sequence for heat pumps with electric heat.
Specifications for the CB5000 Series communication board.
Explains the meaning of different LED lights on the CB5000 board.
Notes on accessing the system without special software.
Configuration settings for the network interface, including IP address and gateway.
Details the general setpoints for controller configuration, with default values.
Configuration of alarm thresholds for low and high temperatures.
Options for overriding system operation, like cooling/heating overrides.
Configuration for sending email alerts for specific system events.
Procedure to lock and unlock the controller to prevent unauthorized changes.
An index listing various controller connection diagrams and their corresponding page numbers.
Wiring diagram for 1-stage AC units without economizers.
Wiring for 1-stage AC units with alarm board and CB5000.
Wiring diagram for 1-stage AC units with JADE economizers.
Wiring for 1-stage AC units with JADE economizers, alarm board, and CB5000.
Wiring diagram for 2-stage AC units without economizers.
Wiring for 2-stage AC units with alarm board and CB5000.
Wiring diagram for 2-stage AC units with JADE economizers.
Wiring for 2-stage AC units with JADE economizers, alarm board, and CB5000.
Wiring diagram for 1-stage AC units without economizers.
Wiring for 1-stage AC units with alarm board and CB5000.
Wiring diagram for 1-stage AC units with WECOP economizers.
Wiring for 1-stage AC units with WECOP economizers, alarm board, and CB5000.
Wiring diagram for 1-stage AC units without economizers.
Wiring for 1-stage AC units with alarm board and CB5000.
Wiring diagram for 1-stage AC units with ECONWM economizers.
Wiring for 1-stage AC units with ECONWM economizers, alarm board, and CB5000.
Wiring diagram for 1-stage AC units with EIFM economizers.
Wiring for 1-stage AC units with EIFM economizers, alarm board, and CB5000.
Wiring diagram for 2-stage AC units without economizers.
Wiring for 2-stage AC units with alarm board and CB5000.
Wiring diagram for 2-stage AC units with ECONWM economizers.
Wiring for 2-stage AC units with ECONWM economizers, alarm board, and CB5000.
Wiring diagram for 2-stage AC units with EIFM economizers.
Wiring for 2-stage AC units with EIFM economizers, alarm board, and CB5000.
Wiring diagram for heat pumps without economizers.
Wiring for heat pumps with alarm board and CB5000.
Wiring diagram for heat pumps without economizers.
Wiring for heat pumps with alarm board and CB5000.
Wiring diagram for a single unit application with an alarm board.
Details on the optional 2nd stage cooling alarm output and its use.
How to connect and use refrigerant pressure lockout alarms.
Describes two sequences for emergency ventilation using economizers.
Guides on swapping units, entering program mode, and using controller buttons.
How to activate and cancel the temporary 1-hour comfort setpoint adjustment.
Explains how to navigate and change settings within the controller's programming menu.