What to do if Bardac E3 DC Drives show drive internal temperature too high?
J
john16Sep 12, 2025
If you are experiencing a 'Drive internal temperature too high' error with your Bardac DC Drives, it suggests a fault on the output, such as a missing phase or unbalanced motor phase currents. Check the motor and its connections.
P
Pamela AguilarSep 12, 2025
Why Bardac DC Drives show over voltage on DC bus?
D
Deborah AdkinsSep 12, 2025
If you're experiencing an over voltage on the DC bus of your Bardac DC Drives, it could be due to the incoming supply voltage being too low. Check the incoming power supply voltage and all components in the power feed line to the drive.
D
Diane EdwardsSep 10, 2025
How to fix heatsink over temperature in Bardac E3?
W
William JacksonSep 12, 2025
If your Bardac DC Drives unit's heatsink is overheating, it indicates that the drive is too hot. Ensure that the ambient temperature around the drive is within the specified limits. Also, make sure there's enough air circulating freely around the drive for cooling.
M
Michelle FosterSep 9, 2025
Why Bardac E3 DC Drives show output over current?
J
Julie SmithSep 9, 2025
If your Bardac DC Drives unit displays an 'Output Over Current' error, it might be due to an excessive or sudden load on the motor. To resolve this, verify that the supply voltage is within the specified tolerance for the drive.
K
Kenneth SimonSep 8, 2025
What to do if Bardac E3 show motor thermal overload?
B
Brittany FloresSep 8, 2025
If your Bardac DC Drives motor is experiencing thermal overload, which means the drive has been running at over 100% of the P-08 value for too long, it's designed to prevent motor damage. If this happens when the motor is decelerating or stopping, you can increase the deceleration time in parameter P-04. Alternatively, you could install a brake resistor and enable the dynamic braking function using parameter P-34.
J
Joshua CastilloAug 23, 2025
What to do if my Bardac E3 show Output Over Current?
D
David WilliamsAug 23, 2025
If your Bardac DC Drives unit displays an Output Over Current error, first check for short circuits on the motor and connection cable. Also, verify that the supply voltage is within the allowed tolerance for the drive, as excess load or shock load on the motor can trigger this fault.
D
Deanna MartinSep 6, 2025
What to do if Bardac E3 shows Internal memory fault (IO)?
K
Kathy LeSep 6, 2025
If your Bardac DC Drives displays an Internal memory fault (IO), press the stop key. If the fault persists, consult your supplier.
H
Heidi WilsonSep 5, 2025
How to fix Brake channel over current on Bardac DC Drives?
E
Edward CruzSep 5, 2025
To fix a Brake channel over current issue on Bardac DC Drives, check the external brake resistor condition and connection wiring.
E
ewilsonSep 4, 2025
What to do for Cooling Fan Fault (IP66 only) in Bardac E3 DC Drives?
A
ashley06Sep 4, 2025
If you encounter a Cooling Fan Fault (IP66 only) in your Bardac DC Drives, check or replace the cooling fan.
J
Jesse WeaverSep 3, 2025
How to troubleshoot CAN comms loss trip on Bardac E3?
J
jonesjasonSep 3, 2025
To troubleshoot a CAN comms loss trip on Bardac DC Drives, check the incoming CAN connection cable and ensure that cyclic communications take place within the timeout limit set in P-36 Index 3.