EasyManua.ls Logo

Barnstead 47900 - Preventative Maintenance; General Cleaning Instructions

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
This unit is equipped with a venting system
on the top of the furnace. This is for the
removal of fumes from the chamber of the
unit.
Contamination is a major cause of element
failure, therefore, remove all fume forming
material before heating. (e.g. clean cutting
oil from tool steel).
Housekeeping is vital to your electric furnace
– KEEP IT CLEAN. Run your furnace up to
871°C (1600°F) empty occasionally to burn
off the contamination that may exist on the
insulation and elements. Maintain 871°C
(1600°F) for at least 4 hours to ensure com-
plete ashing of foreign materials.
Element life is reduced somewhat by repeat-
ed heating and cooling. If the furnace is to
be used again within a few hours, it is best
to keep it at the operating temperature or at
a reduced level such as 260°C (500°F). We
highly recommend that you replace the ther-
mocouple periodically (once every six
months) to ensure temperature accuracy.
General Cleaning Instructions
Wipe exterior surfaces with a lightly damp-
ened cloth containing a mild soap solution.
Preventive Maintenance