Tech 400 User Guide R5 4/1/08
2
IMPORTANT NOTICES
The contents of this manual may not be reproduced or distributed by any
means
electronically, mechanically, recording or
otherwise. All specifications,
illustrations and information contained within this manual are based on the
most current information available at the time of publication. Bartec reserves
the right to make changes at any time without obligation to notify any person or
organization. Bartec will do its best to keep you the customer informed of any
changes that might affect the tools
performance.
FCC Compliance Model: DSW
FCC ID: SX8- DSW IC: 5736A-DSW
This device complies with part 15 of the FCC rules and with RSS-210 of Industry
Canada. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation. Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the
equipment.
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radiocommunications. Operation of this equipment in a
residential area s likely to cause harmful interference in which case the user will
be required to correct the interference at their expense.
The Tech 400’s internal rechargeable battery is non-user replaceable. It can be
recharged only using the Bartec supplied ‘Kings’ ‘plug top’ charging unit. The
full capacity of the battery is reached only after a few charge/discharge cycles.
This capacity reduces as the battery comes to the end of its life. Contact Bartec
for advice on replacement.
Data (measurements) from TPM’s is reproduced as provided by the sensor. Note
that the sensor provides absolute (gauge) pressure corrected for an assumed
ambient pressure. The actual pressure relativeto real ambient may be slightly
different. Hence hand help gaugesand vehicle dash displays may give slightly
different pressure readings. Pressure is only available from Schrader TPMS on the
‘Select by Vehicle’ method.
Tech 400 User Guide R5 4/1/08
27
A typical screen seen during communication is:-
During vehicle communication, the ESC k
e
y
is inhibited.
Should
the
process be commenced inadvertently, the tool can be left to
timeout of its own accord - approximately 20 seconds.
To disconnect the OBD interface, reverse the connection method,
no
ting that
removal of the cable is done by lightly pulling on the
knurled metal ring as shown:

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bartec TECH400 and is the answer not in the manual?

Bartec TECH400 Specifications

General IconGeneral
BrandBartec
ModelTECH400
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals