ELECTRICAL INSTRUCTIONS
The DFG280 machine is supplied with a specially commissioned 110V electric motor and
starter switch assembly. Each unit is fully tested, and the safety overload relays have been
calibrated and set according to the manufacturer’s specifications. In the event of the
malfunction on a new machine the owner should first check that the power supply on-site is
suitable and adequate.
DFG280-6 (120V)
• The 120V motor requires a 15 Amp supply.
All cables should be fully uncoiled and never left wrapped around cable reels or tied in loops.
The motor is protected with a safety trip in the panel. Should the trip be activated, it will reset
automatically after cooling down. Damage will occur if the motor repeatedly cuts out. Possible
causes are either an inadequate power supply, overloading of the machine, or an electrical
fault.