10 SPECIFICATIONS
10.1 General
Accuracy:
±0.5% of full scale
Sampling rate:
500 Hz
Power:
AC or rechargeable battery, with multi-step low battery indicator
Battery life:
Backlight on: up to 7 hours of continuous use
Backlight off: up to 24 hours of continuous use
Safe overload:
200% of full scale (display shows “OVER” at 110% and above)
Weight:
12-0340 12-0341: 0.7 lb [0.33 kg]
12-0342 12-0343: 0.9 lb [0.41 kg]
Environmental
requirements:
40 - 100°F, max. 93% humidity, non-condensating
Warranty:
3 years (see individual statement for further details)
10.2 Factory Default Settings
Parameter
Setting
Filters
Current
8
Displayed
128
Backlight
Auto
Minutes
1
Automatic Shutoff
Enabled
Minutes
5
LCD Contrast
10
Initial Mode
Real Time
Units
lbF
10.3 Capacity, Resolution & Load Cell Deflection
Model
lbF
kgF
N
12-0340
50 x 0.05
25 x 0.02
250 x 0.2
12-0341
100 x 0.1
50 x 0.05
500 x 0.5
12-0342
250 x 0.2
100 x 0.1
1000 x 1
12-0343
500 x 0.5
250 x 0.2
2500 x 2