Operation and Features
3-16 BASLER A302f
DRAFT
Test Image Two
As shown in Figure 3-13, test image two consists of lines with several gray scale gradients ranging
from 0 to 255. If the camera is operating at full 782 x 582 resolution when the test images are
generated:
lines 1, 2, 3, and 4 start with a gray value of 0 for the first pixel,
lines 5, 6, 7, and 8 start with a gray value of 1 for the first pixel,
lines 9, 10, 11, and 12 start with a gray value of 2 on the first pixel, and so on.
(If the camera is operating at a lower resolution when the test images are generated, the basic
appearance of the test pattern will be similar to Figure 3-13, but the staring pixel values on each
line will not be as described above.)
The mathematical expression for test image two is:
Figure 3-13: Test Image Two
Test Image Three
Test image three (not shown) is similar to test image one but it is not stationary. The image moves
by 1 pixel from right to left whenever a one-shot, multi-shot or continuous-shot command signal is
sent to the camera.
*
Test images are an advanced feature and may not be supported by the camera driver
software that you are using to operate your camera.