EasyManuals Logo

Basler V3E Z1P B2C1F User Manual

Default Icon
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
9137200997 Rev D BE1-51 Tests and Adjustments i
SECTION 5 TESTS AND ADJUSTMENTS
TABLE OF CONTENTS
SECTION 5 TESTS AND ADJUSTMENTS............................................................................................ 5-1
GENERAL.............................................................................................................................................. 5-1
REQUIRED TEST EQUIPMENT ........................................................................................................... 5-1
OPERATIONAL TEST ........................................................................................................................... 5-1
Preliminary Instructions...................................................................................................................... 5-1
Time Overcurrent Pickup Test............................................................................................................ 5-3
Neutral Defeat Test ............................................................................................................................ 5-5
Timed Output Test.............................................................................................................................. 5-5
Instantaneous Overcurrent Pickup Test............................................................................................. 5-7
ADJUSTMENTS OF CONTROLS FOR RELAY OPERATION ............................................................. 5-8
TAP and TAP (NEUTRAL) Selector Setting....................................................................................... 5-8
Time Overcurrent Curve Selection (Timing Type Z1, Z2, and Z3 Only) ............................................ 5-9
Time Delay Selection ....................................................................................................................... 5-10
Neutral Time Delay Selection........................................................................................................... 5-10
INST 1 Control Setting ..................................................................................................................... 5-10
INST 2 Control Setting ..................................................................................................................... 5-11
Figures
Figure 5-1. Test Setup for Sensing Input Type K (Single-Phase Sensing)............................................... 5-2
Figure 5-2. Test Setup for Sensing Input Type G (Three-Phase Sensing)............................................... 5-2
Figure 5-3. Test Setup for Sensing Input Type H or V (Three-Phase with Neutral Sensing).................... 5-3
Figure 5-4. Test Setup for Sensing Input Type I or X (Two-Phase with Neutral Sensing)........................ 5-3
Courtesy of NationalSwitchgear.com

Table of Contents

Other manuals for Basler V3E Z1P B2C1F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler V3E Z1P B2C1F and is the answer not in the manual?

Basler V3E Z1P B2C1F Specifications

General IconGeneral
BrandBasler
ModelV3E Z1P B2C1F
CategoryRelays
LanguageEnglish

Related product manuals