INSTRUCTION MANUAL
FOR
GENERATOR PROTECTIVE RELAY
BE3-GPR
SYNC-CHECK REV-PWRUNDER OVER
VOLTAGE CURRENT FREQUENCY TIME-DELAYDELTAANGLE RESETTRIP
VOLTS
AMPS
WATTS
HERTZ
SECONDS
DEGREES
ON
OFF
PHASE REACTIVE GND-FAULT DEAD-BUS
12
35343326 3191113 16763
3736 38 39 40 41 42 43 51504948474644 45 59585756555452 53 67666564636260 61 68 69 70
BE3-GPR
Generator
Protective
Relay
Select
Lower
Raise
Sync
24 81210 18 20 2422 321
Basler
Publication: 9 2782 00 990
Revision: F 01/2000

Table of Contents

Questions and Answers

  • M
    michaelsmithAug 12, 2025
    How to fix no display on Basler Relays?
    • S
      Steven MorrisAug 12, 2025
      If your Basler Relays display is not showing anything, make sure to check the battery input connections. Confirm that the voltage applied is between 8 to 32 volts and that the polarity is correct.
  • D
    daniel51Aug 15, 2025
    What to do if Basler Relays trips occur during generator ramp-up or shutdown?
    • M
      Matthew PopeAug 16, 2025
      If your Basler Relays are tripping during generator ramp-up or shutdown, you can close the output disable to disable trips during these periods. Alternatively, consider increasing the trip timing.
  • N
    nathan95Aug 19, 2025
    Why no communications with Basler Relays?
    • H
      hrodriguezAug 20, 2025
      If you're experiencing issues with no communications with your Basler Relays, check the serial port connections. Ensure your host computer is configured for a 2400 baud rate, 8 data bits, 1 stop bit, and no parity. Also, verify that the Rx and TX lines are connected correctly and not switched.
  • A
    asmithAug 23, 2025
    Why Basler Relays phase balance always tripped?
    • J
      johnsonamandaAug 25, 2025
      If your Basler Relays are always tripping due to phase balance, verify that the phase rotation is ABC and that the system application is appropriate.
  • M
    Miss Angela MoranAug 27, 2025
    What to do if no data can be entered from the front panel on Basler Relays?
    • H
      hhigginsAug 27, 2025
      If you cannot enter data from the front panel of your Basler Relays, verify that the program enable jumper is installed.
  • Z
    Zachary LeeAug 31, 2025
    Why does Basler Relays display always flashes a previous trip condition?
    • V
      Victoria WangAug 31, 2025
      If the display on your Basler Relays always flashes a previous trip condition, momentarily close the trip reset input or enable the automatic trip reset option.
  • E
    Edwin NewtonSep 3, 2025
    Why reactive current pickups are not correct on Basler Relays?
    • R
      Ryan RobertsonSep 3, 2025
      If the reactive current pickups are not correct on your Basler Relays, verify that the sensing method is correct and appropriate for the application. Also, verify that CT B input is sensing phase B current and is in the correct polarity.
  • S
    srodriguezSep 7, 2025
    Why reverse power pickups are not correct on Basler Relays?
    • D
      David DoyleSep 7, 2025
      If the reverse power pickups are not correct on your Basler Relays, verify the sensing method is correct and appropriate for the application. Also, verify that CT B input is sensing phase B current and is in the correct polarity.

Summary

SECTION 1 GENERAL INFORMATION

SECTION 4 INSTALLATION

Connections

General overview of wiring and terminal connections.

SECTION 5 NGF COMMUNICATIONS

Initializing Communications with the BE3-GPR

Steps to establish communication between PC and relay.

Sending, Getting, and Displaying Data

Managing data transfer between PC and relay.

SECTION 7 TESTING

Test Setup

Initial steps for setting up the test environment.

Protective Functions

Overview of testing individual protective functions.

Overvoltage Trip (Line-To-Neutral Voltage Sensing)

Tests the overvoltage trip function with line-to-neutral sensing.

Overvoltage Trip (Line-To-Line Voltage Sensing)

Tests the overvoltage trip function with line-to-line sensing.

Neutral Ground Fault Trip (5 A NGF CT Current Sensing)

Tests the NGF trip function with 5A CTs.

Overcurrent Trip (5 A A, B, or C CT Current Sensing)

Tests the overcurrent trip function with 5A CTs.

Reactive Current Trip (5 A CT B Current Sensing)

Tests the reactive current trip function with 5A CTs.

Reverse Power Trip (5 A CT B Current Sensing)

Tests the reverse power trip function with 5A CTs.

Reverse Power Trip (1 A CT B Current Sensing)

Tests the reverse power trip function with 1A CTs.

Neutral Ground Fault Trip (1 A NGF CT Current Sensing)

Tests the NGF trip function with 1A CTs.

Overcurrent Trip (1 A A, B, or C CT Current Sensing)

Tests the overcurrent trip function with 1A CTs.

Sync-Check Functions

Overview of testing sync-check and dead bus functions.

Sync-Check

Detailed steps to test the sync-check functionality.

Dead Bus

Detailed steps to test the dead bus functionality.

SECTION 8 MAINTENANCE

Troubleshooting

Provides a table of common symptoms and their recommended solutions.

Basler BE3-GPR Specifications

General IconGeneral
BrandBasler
ModelBE3-GPR
CategoryRelays
LanguageEnglish