Instruction Manual Junior II
23
2. Filter cartridge 059183: lifetime [hours]
Filling pressure p = 200 bar
Junior II
Ambient temperature
tU [°C]
Final separator temperature
tAb [°C]
Delivery
Q [l/min]
100
10 20 - 24 22 - 18
15 25 - 29 17 - 13
20 30 - 34 13 - 10
25 35 - 39 10 - 8
30 40 - 44 8 - 6
35 45 - 49 6 - 5
40 50 - 54 5 - 4
Filling pressure p = 300 bar
Junior II
Ambient temperature
tU [°C]
Final separator temperature
tAb [°C]
Delivery
Q [l/min]
100
10 20 - 24 34 - 27
15 25 - 29 25 - 20
20 30 - 34 19 - 15
25 35 - 39 15 - 12
30 40 - 44 11 - 9
35 45 - 49 9 - 7
40 50 - 54 7 - 6
Filter cartridge 059183: bottle fillings [number] molecular sieve mass mMS [g] = 58
Ambient
temperature
tU [°C]
Final separa
tor tempera
ture
tAb [°C]
Air humidity,
saturated
X [g/m
3
]
processable air volume Va
[m
3
]
at pressure p [bar]
Number of bottle fillings n
acc. to bottle size
200 300 7 l 10 l 12 l
10 20 - 24 17,31 - 21,80 134 - 106 201 - 160 96 - 76 67 - 53 56 - 44
15 25 - 29 23,07 - 28,79 101 - 81 151 - 121 72 - 58 50 - 40 42 - 34
20 30 - 34 30,40 - 37,63 76 - 62 114 - 92 55 - 44 38 - 31 32 - 26
25 35 - 39 39,65 - 48,64 59 - 48 88 - 72 42 - 34 29 - 24 24 - 20
30 40 - 44 51,21 - 62,41 45 - 37 68 - 56 32 - 27 23 - 19 19 - 15
35 45 - 49 65,52 - 79,28 35 - 29 53 - 44 25 - 21 18 - 15 15 - 12
40 50 - 54 83,08 - 99,85 28 - 23 42 - 35 20 - 17 14 - 12 12 - 10
Bottle volume VF [m
3
]
Bottle size at pressure p [bar]
l [ltr.] 200 300
7 1,4 2,1
10 2 3
12 2,4 3,6
Number of bottle fillings n=
processable air volume / bottle volume = Va / VF
Bottle volume: VF [m
3
] = p [bar] x l [l] / 1000 [l/m
3
]
Processable air volume: Va [m
3
] = 0,2 x mMS [g] / (X [g/m
3]
/
p [bar]) = 0,2 x p [bar] x mMS [g] / X [g/m
3
]
Filter cartridge lifetime: tp [h] = Va [m
3
] / (Q [m
3
/min] x 60
[min/h])