Manual for BAUER RAINSTAR A3
14
When the full operating pressure has been reached and clear
water is discharged at the sprinkler's nozzle in a full jet without
air bubbles, push the gear shift lever to the "PE-pipe
retraction" position.
The reel starts to rewind the PE-pipe.
3.1.4 SPEED ADJUSTMENT with mechanical regulation
Adjust the speed only when the PE-pipe already has been rewound by half a
winding and/or when it is stretched.
Slower Faster
Loosen the knurled nuts (for fixation of the adjusting lever).
Set the retraction speed which can be read on the
speedometer (optional) by means of the adjusting lever. Then
lock the adjusting lever again with the knurled nuts.
Retractionspeedm/h 10 20 30
Waterflow10m³/h 2 1‐
14m³/h 2 1 1
18m³/h 2 2 1
In the table you find the hole position.
Hole 1 is the bottom hole.
Note:
Smalls corrections deviating from the chart could be necessary, because the friction resistance of the
Pipe on the ground is equal.
IMPORTANT!