Do you have a question about the Bauer Ecostar 6000 and is the answer not in the manual?
Screen Mesh Size | 120 mesh |
---|---|
Filter Type | Screen |
Material | Polyamide |
Inlet Connection | 2" BSP |
Outlet Connection | 2" BSP |
Device enters sleep mode after inactivity; restart via touchscreen.
Window for changing values or selecting options, used for data entry.
On-screen keyboard for text input and data entry.
Procedure for entering PIN codes to access menus, including master PIN.
Shows irrigation status, errors, battery level; access details via info button.
Configure pre- or post-irrigation based on distance and time parameters.
Set automatic irrigation start time; enters 'waiting to irrigate' mode.
Displays calculated stop time or irrigation duration; view toggle available.
Control turbine speed for gear changes; slows turbine down to zero.
Activate or deactivate the sprinkler function.
Activate sprinkler based on time after start and retraction distance.
Activate sprinkler based on remaining pipe length until irrigation ends.
Activate sprinkler at a specific time for a defined duration.
Activate or deactivate the signal lamp feature.
Specify extension distance that triggers the signal lamp.
Define how long the signal lamp should illuminate or flash.
Access to select and create irrigation programs.
Configure machine settings and pipe length.
Configure machine parameters (PIN protected).
Configure telephone numbers and SMS settings.
Configure system parameters like date, time, language.
Access troubleshooting information (PIN protected).
View operating hours, water consumption, battery voltage.
Reset ECOSTAR, save/load settings (PIN protected).
Configure target speed, pre-irrigation, and post-irrigation.
Set irrigation amount for programs; used when no zones are created.
Configure pre-irrigation for the current program.
Configure post-irrigation for the current program.
Configure zone start, speed, and end for up to 4 zones.
Set retraction speed or irrigation amount for a specific zone.
Define sprinkler to machine distance at zone start.
Define sprinkler to machine distance at zone end.
Define speed settings for zones based on distance.
Configure automatic start time, pause, and pause length.
Set automatic irrigation start time; '00:00' deactivates.
Set irrigation pause time; '00:00' deactivates pause.
Specify the duration of the irrigation pause.
Configure switch-off, extended length, monitoring time, pressure monitoring.
Select shut-off: low pressure, over-pressure, or none.
Change or input the currently extended length.
Set time for irrigation stop if error or speed not met.
Select pressure monitoring via switch or sensor.
Configure pressure mode, monitoring time, min. pressure, units.
Select pressure monitoring for starting or monitoring.
Time for ECOSTAR response to pressure fluctuations.
Set minimum pressure; irrigation stops if it falls below.
Select units: mm or m/h for retraction speed.
Configure low-pressure start, flow, and strip width.
Open valve on start or low/absent pressure.
Input water meter flow impulse value.
Enter known flow rate or 0; speed calculated based on flow.
Configure strip width for sprinkler pattern.
Configure nozzle diameter, pressure, and characteristics alpha.
Specify the diameter of the endgun nozzle.
Set the nozzle pressure.
Set nozzle characteristics value from manufacturer table.
View pipe length, diameter, reel core diameter, rot./position.
Input PE pipe length in meters.
Input internal diameter of PE pipe in millimeters.
Input diameter of the reel core in millimeters.
Input rotations per position.
Details: teeth count, magnets, pipe ovality.
Number of large teeth on the reel sprocket.
Number of small teeth on the reel sprocket.
Number of magnets on disk for speed measurement.
Pipe ovality setting, defaults to 89%.
Configure motor impulses, time between impulses, short impulses.
Duration of first impulse to shut-off valve during closing.
Duration of subsequent impulses to shut-off valve.
Time interval between short impulses to the valve.
Count of short impulses to the shut-off valve.
Configure valve closing, low pressure, turbine impulse, service settings.
Shut-off delay for the valve.
Time valve stays open during shut-off at low pressure.
Length of the first impulse to the turbine.
Configure regulation-related settings.
Manage PINs, default data, slow valve opening.
Set the PIN code for the machine data menu.
Set the PIN code that accesses all menus.
Accept current machine data as default settings.
Open valve slowly using closing settings.
Configure connection, signal strength, PIN, GPS.
Set connection: OFF, SMS, or DATA.
View current signal strength.
Change PIN code for this menu.
Switch the GPS function on or off.
Configure telephone numbers for SMS.
Set and configure one or more telephone numbers.
Configure number, active status, error message status.
Enter telephone number, including country code (+xx).
Activate telephone for sending commands to ECOSTAR.
Activate ECOSTAR error message notifications.
Configure server IP, port, and address for SmartRain.
IP address of the SmartRain server.
Port number of the SmartRain server.
Address assigned to ECOSTAR for SmartRain.
Configure internet/APN, username, password, ping time.
APN of the SIM card network provider.
Username for internet connection (network dependent).
Password for internet connection (network dependent).
Time for internet connection reestablishment.
List of commands for start, stop, status, speed, rain.
List of cases causing ECOSTAR to send messages.
Configure language, time, date, and units.
Select language or import additional languages.
Set the current time.
Set the current date.
Select unit system: metric or imperial.
Configure energy management, calibration, PIN.
Set display brightness and dimming/off times.
Recalibrate touchscreen by touching points sequentially.
Set the PIN code for this menu.
View installed languages; enable selection or import.
Choose language; 'select' button activates it.
Import or update languages using a USB stick.
Configure power saving modes (Permanent, Summer, Winter) and timing.
Select power saving modes: Permanent, Summer, or Winter.
Set time after which the display is dimmed.
Set time for ECOSTAR to enter sleep mode.
Set time for ECOSTAR to wake from sleep mode.
Configure communication disable, control tolerance, stop irrigation, brightness.
Disable communication if battery status remains low.
Increase speed control tolerance if battery status is low.
End irrigation if battery status remains low.
Set display brightness, independent of power saving mode.
View software version, inputs, stop/length sensor status.
Display software version and ECOSTAR information.
Check the status of system inputs.
Check if the stop sensor is active.
Check the status of the length sensor.
View turbine/valve current, temperature, manual operation.
Display last received current of the turbine.
Display last received current of the shut-off valve.
Display current temperature of the control unit.
Manually switch ECOSTAR outputs on and off.
View software version and operating hours.
Display software version and ECOSTAR information.
Time turbine has been active in minutes.
Time shut-off valve has been active in minutes.
Time irrigation has been active.
View water consumption, activities, voltage, diagnosis.
Display data about water consumption.
Load logs for GUI, motor/sensor, irrigation.
Display electronics voltage and battery charge state.
Navigate to the Diagnosis menu.
View consumption since start, last irrigation, and total.
Display water consumption of current irrigation.
Display water consumption of last irrigation.
Display total water consumption (can be changed).
Detailed consumption list, exportable to USB.
Access logs for GUI, motor/sensor, and irrigation.
Records operations information.
Records inputs and outputs information.
Records irrigation information and error messages.
Table of last 40 log entries with date and time.
Save/load parameters, reset factory settings, import icons.
Save machine parameters and settings to USB.
Load machine parameters and settings from USB.
Reset the ECOSTAR to factory settings.
Import icons from a USB stick.
Delete icons, reset, restart, export language.
Delete icons.
Reset all settings.
Restart the ECOSTAR 6000.
Export the current language file.
List of connection numbers and their names.
List of names for connections and sensors.
Detail wire colors for each connection.
Recalibrate touchscreen by pressing button during startup.
Reset ECOSTAR to standard settings via button combination.
Capture current display using USB stick and button press.
Download and unpack update files onto USB stick.
Insert USB stick into the Ecostar6000's rear port.
Navigate Backup menu, select Restart for update.
Check installed version via Menu -> INFO -> Info.
Procedure to remove a defective fuse from its holder.
Insert a replacement fuse into the device holder.
Open Modem menu to configure SmartRain settings.
Set Connection to DATA and GPS to On.
Ensure server IP, port are correctly configured.
Use Bauer SIM factory settings or contact provider.
Troubleshoot blank screen: check power, brightness, sleep mode.
Troubleshoot turbine not starting: check magnet, stop sensor.
Troubleshoot incorrect measurements: check cable, length sensor.
Check website for latest software version for other errors.
Device dimensions: 170 x 140 x 100 mm.
Operating voltage: 10-15V DC.
Fuse requirement: 8 A (fast).