EasyManua.ls Logo

Bauer Ecostar 6000 User Manual

Bauer Ecostar 6000
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Version V1-9 / XI-2018
Software V04.18 or higher
EN

Other manuals for Bauer Ecostar 6000

Question and Answer IconNeed help?

Do you have a question about the Bauer Ecostar 6000 and is the answer not in the manual?

Bauer Ecostar 6000 Specifications

General IconGeneral
Screen Mesh Size120 mesh
Filter TypeScreen
MaterialPolyamide
Inlet Connection2" BSP
Outlet Connection2" BSP

Summary

ECOSTAR Operation and Input

ECOSTAR Sleep Mode

Device enters sleep mode after inactivity; restart via touchscreen.

ECOSTAR Dialog Window

Window for changing values or selecting options, used for data entry.

ECOSTAR Touchscreen Keyboard

On-screen keyboard for text input and data entry.

ECOSTAR PIN Code Entry

Procedure for entering PIN codes to access menus, including master PIN.

ECOSTAR Main Screen Overview

ECOSTAR Info Screen Display

Shows irrigation status, errors, battery level; access details via info button.

ECOSTAR Pre/Post Irrigation Setup

Configure pre- or post-irrigation based on distance and time parameters.

ECOSTAR Automatic Start Time

Set automatic irrigation start time; enters 'waiting to irrigate' mode.

ECOSTAR Irrigation Stop Time

Displays calculated stop time or irrigation duration; view toggle available.

ECOSTAR Turbine Gear Shift

Control turbine speed for gear changes; slows turbine down to zero.

ECOSTAR Sprinkler Configuration

ECOSTAR Sprinkler Status

Activate or deactivate the sprinkler function.

Sprinkler Activation by Time/Distance

Activate sprinkler based on time after start and retraction distance.

Sprinkler Activation by Pipe Length

Activate sprinkler based on remaining pipe length until irrigation ends.

Sprinkler Activation by Schedule

Activate sprinkler at a specific time for a defined duration.

ECOSTAR Signal Lamp Settings

ECOSTAR Signal Lamp Status

Activate or deactivate the signal lamp feature.

ECOSTAR Signal Lamp Distance

Specify extension distance that triggers the signal lamp.

ECOSTAR Signal Lamp Duration

Define how long the signal lamp should illuminate or flash.

ECOSTAR Main Menu Navigation

ECOSTAR Irrigation Menu

Access to select and create irrigation programs.

ECOSTAR Base Settings

Configure machine settings and pipe length.

ECOSTAR Machine Data

Configure machine parameters (PIN protected).

ECOSTAR SMS/Modem Menu

Configure telephone numbers and SMS settings.

ECOSTAR System Settings

Configure system parameters like date, time, language.

ECOSTAR Service Menu

Access troubleshooting information (PIN protected).

ECOSTAR Info Menu

View operating hours, water consumption, battery voltage.

ECOSTAR Backup Menu

Reset ECOSTAR, save/load settings (PIN protected).

ECOSTAR Irrigation Menu

ECOSTAR Irrigation Program Settings 1/3

Configure target speed, pre-irrigation, and post-irrigation.

ECOSTAR Target Irrigation Amount

Set irrigation amount for programs; used when no zones are created.

ECOSTAR Program Pre-Irrigation

Configure pre-irrigation for the current program.

ECOSTAR Program Post-Irrigation

Configure post-irrigation for the current program.

ECOSTAR Zone Settings

ECOSTAR Zone Settings Configuration

Configure zone start, speed, and end for up to 4 zones.

ECOSTAR Zone Speed Configuration

Set retraction speed or irrigation amount for a specific zone.

ECOSTAR Zone Start Distance

Define sprinkler to machine distance at zone start.

ECOSTAR Zone End Distance

Define sprinkler to machine distance at zone end.

ECOSTAR Irrigation Program Details

ECOSTAR Irrigation Program Settings 2/3

Define speed settings for zones based on distance.

ECOSTAR Irrigation Program Settings 3/3

Configure automatic start time, pause, and pause length.

ECOSTAR Automatic Start Time Setup

Set automatic irrigation start time; '00:00' deactivates.

ECOSTAR Irrigation Pause Control

Set irrigation pause time; '00:00' deactivates pause.

ECOSTAR Pause Duration Setting

Specify the duration of the irrigation pause.

ECOSTAR Base Settings Configuration

ECOSTAR Base Settings 1/4

Configure switch-off, extended length, monitoring time, pressure monitoring.

ECOSTAR Switch Off Methods

Select shut-off: low pressure, over-pressure, or none.

ECOSTAR Extended Length

Change or input the currently extended length.

ECOSTAR Monitoring Time

Set time for irrigation stop if error or speed not met.

ECOSTAR Pressure Monitoring

Select pressure monitoring via switch or sensor.

ECOSTAR Base Settings 2/4

Configure pressure mode, monitoring time, min. pressure, units.

ECOSTAR Advanced Base Settings

ECOSTAR Pressure Mode

Select pressure monitoring for starting or monitoring.

ECOSTAR Pressure Monitoring Time

Time for ECOSTAR response to pressure fluctuations.

ECOSTAR Minimum Pressure

Set minimum pressure; irrigation stops if it falls below.

ECOSTAR Unit Selection

Select units: mm or m/h for retraction speed.

ECOSTAR Base Settings 3/4

Configure low-pressure start, flow, and strip width.

ECOSTAR Low Pressure Start

Open valve on start or low/absent pressure.

ECOSTAR Flow Impulse

Input water meter flow impulse value.

ECOSTAR Flow Rate

Enter known flow rate or 0; speed calculated based on flow.

ECOSTAR Strip Width

Configure strip width for sprinkler pattern.

ECOSTAR Nozzle Settings

ECOSTAR Base Settings 4/4

Configure nozzle diameter, pressure, and characteristics alpha.

ECOSTAR Nozzle Diameter

Specify the diameter of the endgun nozzle.

ECOSTAR Nozzle Pressure

Set the nozzle pressure.

ECOSTAR Nozzle Characteristics Alpha

Set nozzle characteristics value from manufacturer table.

ECOSTAR Machine Data

ECOSTAR Machine Data 1/5

View pipe length, diameter, reel core diameter, rot./position.

ECOSTAR Pipe Length

Input PE pipe length in meters.

ECOSTAR Pipe Diameter

Input internal diameter of PE pipe in millimeters.

ECOSTAR Reel Core Diameter

Input diameter of the reel core in millimeters.

ECOSTAR Rotations Per Position

Input rotations per position.

ECOSTAR Machine Data Details

ECOSTAR Machine Data 2/5

Details: teeth count, magnets, pipe ovality.

ECOSTAR Number of Teeth Big

Number of large teeth on the reel sprocket.

ECOSTAR Number of Teeth Small

Number of small teeth on the reel sprocket.

ECOSTAR Number of Magnets

Number of magnets on disk for speed measurement.

ECOSTAR Pipe Ovality

Pipe ovality setting, defaults to 89%.

ECOSTAR Machine Data 3/5

Configure motor impulses, time between impulses, short impulses.

ECOSTAR First Motor Impulse

Duration of first impulse to shut-off valve during closing.

ECOSTAR Short Motor Impulse

Duration of subsequent impulses to shut-off valve.

ECOSTAR Time Between Impulses

Time interval between short impulses to the valve.

ECOSTAR Number of Short Impulses

Count of short impulses to the shut-off valve.

ECOSTAR Machine Control Settings

ECOSTAR Machine Data 4/5

Configure valve closing, low pressure, turbine impulse, service settings.

ECOSTAR Valve Closing Delay

Shut-off delay for the valve.

ECOSTAR Low Pressure Valve Closing

Time valve stays open during shut-off at low pressure.

ECOSTAR First Turbine Impulse

Length of the first impulse to the turbine.

ECOSTAR Service Settings

Configure regulation-related settings.

ECOSTAR Machine Data 5/5

Manage PINs, default data, slow valve opening.

ECOSTAR Machine Data PIN

Set the PIN code for the machine data menu.

ECOSTAR Master PIN

Set the PIN code that accesses all menus.

ECOSTAR Set Default Data

Accept current machine data as default settings.

ECOSTAR Slow Valve Opening

Open valve slowly using closing settings.

ECOSTAR SMS/Modem Menu

ECOSTAR SMS/Modem Settings 1/4

Configure connection, signal strength, PIN, GPS.

ECOSTAR Connection Type

Set connection: OFF, SMS, or DATA.

ECOSTAR Signal Strength

View current signal strength.

ECOSTAR SMS/Modem PIN

Change PIN code for this menu.

ECOSTAR GPS Function

Switch the GPS function on or off.

ECOSTAR SMS/Modem Settings 2/4

Configure telephone numbers for SMS.

ECOSTAR Telephone Numbers

Set and configure one or more telephone numbers.

ECOSTAR Telephone and Server Settings

ECOSTAR Telephone Setting 1

Configure number, active status, error message status.

ECOSTAR Telephone Number Input

Enter telephone number, including country code (+xx).

ECOSTAR Number Active

Activate telephone for sending commands to ECOSTAR.

ECOSTAR Error Message Active

Activate ECOSTAR error message notifications.

ECOSTAR SMS/Modem Settings 3/4

Configure server IP, port, and address for SmartRain.

ECOSTAR Server IP Address

IP address of the SmartRain server.

ECOSTAR Server Port

Port number of the SmartRain server.

ECOSTAR SmartRain Address

Address assigned to ECOSTAR for SmartRain.

ECOSTAR Internet and SMS Commands

ECOSTAR SMS/Modem Settings 4/4

Configure internet/APN, username, password, ping time.

ECOSTAR Internet/APN Settings

APN of the SIM card network provider.

ECOSTAR Username

Username for internet connection (network dependent).

ECOSTAR Password

Password for internet connection (network dependent).

ECOSTAR Ping Time

Time for internet connection reestablishment.

ECOSTAR SMS Commands

List of commands for start, stop, status, speed, rain.

ECOSTAR Message Triggers

List of cases causing ECOSTAR to send messages.

ECOSTAR System Settings

ECOSTAR System Settings 1/2

Configure language, time, date, and units.

ECOSTAR Language Selection

Select language or import additional languages.

ECOSTAR Time Setting

Set the current time.

ECOSTAR Date Setting

Set the current date.

ECOSTAR Unit System

Select unit system: metric or imperial.

ECOSTAR System Settings 2/2

Configure energy management, calibration, PIN.

ECOSTAR Energy Management

Set display brightness and dimming/off times.

ECOSTAR Touchscreen Calibration

Recalibrate touchscreen by touching points sequentially.

ECOSTAR System Settings PIN

Set the PIN code for this menu.

ECOSTAR Language Menu

ECOSTAR Language Settings

View installed languages; enable selection or import.

ECOSTAR Select Language

Choose language; 'select' button activates it.

ECOSTAR Import Language Files

ECOSTAR Import Language

Import or update languages using a USB stick.

ECOSTAR Energy Management

ECOSTAR Energy Management 1/2

Configure power saving modes (Permanent, Summer, Winter) and timing.

ECOSTAR Power Saving Mode

Select power saving modes: Permanent, Summer, or Winter.

ECOSTAR Time to Dim

Set time after which the display is dimmed.

ECOSTAR Time to Switch Off

Set time for ECOSTAR to enter sleep mode.

ECOSTAR Time for Standby

Set time for ECOSTAR to wake from sleep mode.

ECOSTAR Energy Management 2/2

Configure communication disable, control tolerance, stop irrigation, brightness.

ECOSTAR Disable Communication

Disable communication if battery status remains low.

ECOSTAR Increase Control Tolerance

Increase speed control tolerance if battery status is low.

ECOSTAR Stop Irrigation

End irrigation if battery status remains low.

ECOSTAR Screen Brightness

Set display brightness, independent of power saving mode.

ECOSTAR Service Menu

ECOSTAR Service/Info 1/2

View software version, inputs, stop/length sensor status.

ECOSTAR Service Info Display

Display software version and ECOSTAR information.

ECOSTAR Input Status

Check the status of system inputs.

ECOSTAR Stop Sensor Status

Check if the stop sensor is active.

ECOSTAR Length Sensor

Check the status of the length sensor.

ECOSTAR Service/Info 2/2

View turbine/valve current, temperature, manual operation.

ECOSTAR Turbine Current

Display last received current of the turbine.

ECOSTAR Shut-off Motor Current

Display last received current of the shut-off valve.

ECOSTAR Electronics Temperature

Display current temperature of the control unit.

ECOSTAR Manual Operation

Manually switch ECOSTAR outputs on and off.

ECOSTAR Information Menu

ECOSTAR Info 1/2 Display

View software version and operating hours.

ECOSTAR General Info Display

Display software version and ECOSTAR information.

ECOSTAR Operating Hours Turbine

Time turbine has been active in minutes.

ECOSTAR Operating Hours Valve

Time shut-off valve has been active in minutes.

ECOSTAR Operating Hours Irrigation

Time irrigation has been active.

ECOSTAR Info 2/2 Display

View water consumption, activities, voltage, diagnosis.

ECOSTAR Water Consumption

Display data about water consumption.

ECOSTAR Show Activities

Load logs for GUI, motor/sensor, irrigation.

ECOSTAR Voltage Electronics

Display electronics voltage and battery charge state.

ECOSTAR Diagnosis Menu

Navigate to the Diagnosis menu.

ECOSTAR Water Consumption Details

ECOSTAR Water Consumption Summary

View consumption since start, last irrigation, and total.

ECOSTAR Consumption Last Start

Display water consumption of current irrigation.

ECOSTAR Consumption Last Irrigation

Display water consumption of last irrigation.

ECOSTAR Total Water Consumption

Display total water consumption (can be changed).

ECOSTAR Consumption List

Detailed consumption list, exportable to USB.

ECOSTAR Activity Logs

ECOSTAR Access Activity Logs

Access logs for GUI, motor/sensor, and irrigation.

ECOSTAR GUI Activity Log

Records operations information.

ECOSTAR Motor/Sensor Log

Records inputs and outputs information.

ECOSTAR Irrigation Log

Records irrigation information and error messages.

ECOSTAR GUI Log Table

Table of last 40 log entries with date and time.

ECOSTAR Backup Menu

ECOSTAR Backup Menu 1/2

Save/load parameters, reset factory settings, import icons.

ECOSTAR Save Parameters

Save machine parameters and settings to USB.

ECOSTAR Load Parameters

Load machine parameters and settings from USB.

ECOSTAR Factory Settings Reset

Reset the ECOSTAR to factory settings.

ECOSTAR Import Icons

Import icons from a USB stick.

ECOSTAR Backup Menu 2/2

Delete icons, reset, restart, export language.

ECOSTAR Reset

Reset all settings.

ECOSTAR Restart

Restart the ECOSTAR 6000.

ECOSTAR Export Language

Export the current language file.

ECOSTAR Connection Plan

ECOSTAR Connection List

List of connection numbers and their names.

ECOSTAR Connection Names

List of names for connections and sensors.

ECOSTAR Wire Color Coding

Detail wire colors for each connection.

ECOSTAR Button Combinations

ECOSTAR Touchscreen Calibration Procedure

Recalibrate touchscreen by pressing button during startup.

ECOSTAR Reset Procedure

Reset ECOSTAR to standard settings via button combination.

ECOSTAR Screenshot Function

Capture current display using USB stick and button press.

ECOSTAR Software Update

ECOSTAR Software Update USB Prep

Download and unpack update files onto USB stick.

ECOSTAR Insert USB Stick

Insert USB stick into the Ecostar6000's rear port.

ECOSTAR Software Update via Backup

Navigate Backup menu, select Restart for update.

ECOSTAR Verify Software Version

Check installed version via Menu -> INFO -> Info.

ECOSTAR Fuse Replacement

ECOSTAR Remove Fuse

Procedure to remove a defective fuse from its holder.

ECOSTAR Insert Fuse

Insert a replacement fuse into the device holder.

ECOSTAR SmartRain Activation

ECOSTAR SmartRain Modem Menu

Open Modem menu to configure SmartRain settings.

ECOSTAR SmartRain Connection/GPS

Set Connection to DATA and GPS to On.

ECOSTAR SmartRain Server Config

Ensure server IP, port are correctly configured.

ECOSTAR SmartRain SIM Settings

Use Bauer SIM factory settings or contact provider.

ECOSTAR Error Troubleshooting

ECOSTAR Blank Display Issues

Troubleshoot blank screen: check power, brightness, sleep mode.

ECOSTAR Turbine Start Failure

Troubleshoot turbine not starting: check magnet, stop sensor.

ECOSTAR Measurement Errors

Troubleshoot incorrect measurements: check cable, length sensor.

ECOSTAR Other Error Resolution

Check website for latest software version for other errors.

ECOSTAR Technical Data

ECOSTAR Dimensions

Device dimensions: 170 x 140 x 100 mm.

ECOSTAR Voltage

Operating voltage: 10-15V DC.

ECOSTAR Fuse Specification

Fuse requirement: 8 A (fast).

Related product manuals