Replacing the mains supply cable
If the mains supply cable is damaged, then it must be replaced with a
suitable replacement.
The mains supply cable should be replaced in accordance with the
following instructions:-
o Switch the appliance off at the socket.
o Open the terminal block on the back of the oven.
o Unscrew the terminal screws fixing the cable.
o Replace the cable with one of the same length and in accordance
with the specification given on page 26.
o The “green-yellow” earth wire must be connected to the terminal
marked . It must be about 10 mm longer than the live and
neutral wires.
o The “blue” neutral wire must be connected to the terminal
marked with letter (N) - the live wire must be connected to the
terminal marked with letter (L).