Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o Remove the pan-stands, burners and flame
spreaders (A).
28
ow).
o Unscrew the injector (B) and replace it with
the stipulated injector for the new gas supply
(see table bel
Burner
Type
Gas Type Pressure
(mbar)
Injector
Marking
(1/100
mm)
Gas
Consumption*
MAX
Power
(kW)
MIN
Power
(kW)
Liquid
gas
G30/
G31
28…
30/37
52 73 g/h Auxiliary
burner
(Ø55mm)
Natural
gas
G20 20 72 95 dm³/h
1.000
0.300
Liquid
gas
G30/
G31
28…
30/37
68 127 g/h Semi-rapid
burner
(Ø75mm)
Natural
gas
G20 20 98 167 dm³/h
1.750
0.440
Liquid
gas
G30/
G31
28…
30/37
88 218 g/h Rapid
burner
(Ø100mm)
Natural
gas
G20 20 116 286 dm³/h
3.000
0.750
LPG G30/G31 28…
30/37
96 262 g/h Wok
burner
(Ø130mm)
Natural
gas
G20 20 135 343 dm³/h
3.600 1.500