EasyManua.ls Logo

Baumatic PCG9110SS - Gas Adjustment: Oven and Grill Conversion; Injector Replacement for Oven and Grill

Baumatic PCG9110SS
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gas adjustment (Conversion to LPG for the oven and grill)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o Free the burners from their
fixing screws.
o Unscrew the injectors and replace
them with the stipulated injector
for the new gas supply (see table
below).
Burner
Type
Gas Type Pressure
Injector
Marking
(1/100
mm)
Gas
consumption*
MAX
Power
(kW)
MIN
Power
(kW)
LPG G30/
G31
28…
30/37
98 305 g/h Main
Oven
Natural
gas
G20 20 150 400 dm³/h
4.200
1.000
LPG G30/
G31
28…
30/37
88 240 g/h Grill
Oven
Natural
gas
G20 20 136 314 dm³/h
3.300
N/A
* In reference conditions, gas temperature 15°C, atmospheric
pressure 1013.25 mbar
IMPORTANT: You must change the oven and grill injectors.
30