Gas adjustment (Conversion to LPG for the oven and grill)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o Free the burners from their
fixing screws.
o Unscrew the injectors and replace
them with the stipulated injector
for the new gas supply (see table
below).
Burner
Type
Gas Type Pressure
Injector
Marking
(1/100
mm)
Gas
consumption*
MAX
Power
(kW)
MIN
Power
(kW)
LPG G30/
G31
28…
30/37
98 305 g/h Main
Oven
Natural
gas
G20 20 150 400 dm³/h
4.200
1.000
LPG G30/
G31
28…
30/37
88 240 g/h Grill
Oven
Natural
gas
G20 20 136 314 dm³/h
3.300
N/A
* In reference conditions, gas temperature 15°C, atmospheric
pressure 1013.25 mbar
IMPORTANT: You must change the oven and grill injectors.
30