EasyManua.ls Logo

Baumer N153 - Page 16

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
N 153
www.baumer.com 16
Offset
Command „U“ is utilized for programming the offset that is added to actual value and actual target. This parame-
ter defines whether the offset is considered in the calculation.
0 = Off Offset disabled. Any offset previously transmitted is NOT added neither to actual value nor
taget.
1 = On Offset enabled. Offset is added to actual value and actual target.
Suppress target
This parameter defines when to indicate the target in the upper line of the display.
0 = On Target indicated if target current value.
1 = Off Target ever indicated, also if target = current value. Indicate arrows too if target current value.
2 = Ever Target and arrows ever suppressed.
Resolution
This parameter defines the resolution of the actual value. Upon altering the resolution the decimal point is
shifted correspondingly by one digit to the right or left, same applies also to actual value and target. The target
values however are not converted correspondingly but only the decimal point is shifted. When editing the ma-
chine please pay attention to defining the resolution first so that the target values are transmitted to the SPAs
with the corresponding resolution.
0 Resolution 1/100 mm resp. 1/1000 inch visualized in display: 000.00 mm resp. 00.000 inch
1 Resolution 1/10 mm resp. 1/100 inch visualized in display: 0000.0 mm resp. 000.00 inch

Related product manuals