37
I N S TA L L E R S e c t i o n ( e n )
7733595 (01-05/19)
P16
0D[LPXP&+VHWSRLQW&
00 &01 &
00
P17 Pump overrun time in heating mode (01-240 minutes) 03
P18 Burner ignition delay in CH mode (00-10 minutes) - 00=10 seconds 03
P19 Manufacturer information 07
P20 Pump overrun time in DHW mode (seconds) 30
P21
$QWLOHJLRQHOORVLVIXQFWLRQ&00…54 'LVDEOHG55…67 (QDEOHG
(set the desired temperature value)
00
P22 Manufacturer information 00
P23 Maximum DHW setpoint temperature (ACS) 60
P24 Manufacturer information 35
P25 1RZDWHUVDIHW\GHYLFH 02
P26..P31 Manufacturer information --
P32..P41 Diagnostics (See SERVICE Instructions) --
P67
Open Therm (OT) settings (See SERVICE Instructions
)
00 3OXJ3OD\
00
14.1 ADJUSTING MAXIMUM HEATING POWER
7KHPD[LPXPKHDWLQJSRZHURIWKHERLOHUFDQEHUHGXFHGWRVXLWWKHUHTXLUHPHQWVRIWKHKHDWLQJV\VWHPLWVHUYHV$WDEOHVKRZLQJ
parameter P13YDOXHVDFFRUGLQJWRWKHGHVLUHGPD[LPXPSRZHUPRGHOLVVKRZQEHORZIRUHDFKVLQJOHERLOHU
To access and edit parameter P13 values, proceed as described in the PARAMETER SETTINGS section.
Boiler model - PARAMETER P13 (%) / Heating output (kW)
kW 1.24 20 - 24 28
0 0
4 2 2 0
5 7 7 4
6 12 12 8
7 17 17 13
8 22 22 17
9 27 27 21
10 32 32 25
12 41 41 33
14 51 51 42
16 61 61 50
18 71 71 58
20 80 80 67
22 90 75
24 100 86