7733595 (01-05/19) 30
I N S TA L L E R S e c t i o n ( e n )
INSTRUCTIONS PRIOR TO INSTALLATION
7KHIROORZLQJQRWHVDQGLQVWUXFWLRQVDUHDGGUHVVHGWR¿WWHUVWRDOORZWKHPWRFDUU\RXWWURXEOHIUHHLQVWDOODWLRQ,QVWUXFWLRQVIRU
lighting and using the boiler are contained in the ‘Instructions for Users’ section. Installation, servicing and running of domestic
JDV¿UHGV\VWHPVPXVWEHSHUIRUPHGE\TXDOL¿HGWHFKQLFLDQVLQFRPSOLDQFHZLWKFXUUHQWUHJXODWLRQV
$GGLWLRQDOO\EHDULQPLQGWKHIROORZLQJ
:KHQ LQVWDOOLQJ WKH XQLW LQ HQYLURQPHQWV ZLWK WHPSHUDWXUHV ORZHU WKDQ & WDNH WKH QHFHVVDU\ SUHFDXWLRQV WR DYRLG WKH
formation of ice in the siphon and in the condensation drain.
This boiler can be connected to any type of double- or single-pipe convector plate, radiator or thermoconvector. Design the
V\VWHPVHFWLRQVDVXVXDOWKRXJKEHDULQJLQPLQGWKHDYDLODEOHÀRZKHDGDWWKHSODWHDVVKRZQLQVHFWLRQ
'RQRWOHDYHDQ\SDFNDJLQJSODVWLFEDJVSRO\VW\UHQHHWFZLWKLQWKHUHDFKRIFKLOGUHQDVWKH\DUHDSRWHQWLDOVRXUFHRI
danger.
Initial lighting of the boiler must be carried out by an authorised Service Engineer, as indicated on the attached sheet.
)DLOXUHWRREVHUYHWKHDERYHZLOOUHQGHUWKHJXDUDQWHHQXOODQGYRLG
ADDITIONAL PUMP WARNING
,IDQDGGLWLRQDOSXPSLVXVHGRQWKHKHDWLQJV\VWHPSRVLWLRQLWRQWKHERLOHUUHWXUQFLUFXLW7KLVZLOODOORZWKHFRUUHFWRSHUDWLRQRI
WKHZDWHUSUHVVXUHVZLWFK
SOLAR WARNING
,IWKHLQVWDQWDQHRXVPL[HGERLOHULVFRQQHFWHGWRDV\VWHPZLWKVRODUSDQHOVWKHPD[LPXPWHPSHUDWXUHRIWKHGRPHVWLFKRWZDWHU
entering the boiler must not exceed 60°C.
Do not leave any packaging (plastic bags, polystyrene, etc.) within the reach of children as they are a potential source of danger.
9. INSTALLING THE BOILER
The template outline is shown in annex "SECTION" C at the end of this manual.
$IWHUGHFLGLQJWKHH[DFWORFDWLRQRIWKHERLOHU¿[WKHWHPSODWHWRWKHZDOO&RQQHFWWKHV\VWHPWRWKHJDVDQGZDWHULQOHWVSUHVHQW
RQWKHORZHUEDURIWKHWHPSODWH0DNHVXUHWKHUHDUSDUWRIWKHERLOHUEDFNLVDVSDUDOOHODVSRVVLEOHWRWKHZDOORWKHUZLVH
VKLPWKHORZHUSDUW)LWWZR*WDSVÀRZDQGUHWXUQRQWKHFHQWUDOKHDWLQJFLUFXLWWKHVHWDSVPDNHLWSRVVLEOHWRFDUU\RXW
LPSRUWDQWRSHUDWLRQVRQWKHV\VWHPZLWKRXWGUDLQLQJLWFRPSOHWHO\,I\RXDUHHLWKHULQVWDOOLQJWKHERLOHURQDQH[LVWLQJV\VWHPRU
UHSODFLQJRQHDVZHOODVWKHDERYH¿WDVHWWOLQJWDQNXQGHUWKHERLOHURQWKHV\VWHPUHWXUQOLQHLQRUGHUWRFROOHFWDQ\GHSRVLWV
DQGVFDOHFLUFXODWLQJLQWKHV\VWHPDIWHUÀXVKLQJ$IWHU¿[LQJWKHERLOHUWRWKHWHPSODWHFRQQHFWWKHÀXHDQGDLUGXFWVVXSSOLHG
DVDFFHVVRULHVDVGHVFULEHGLQWKHIROORZLQJVHFWLRQV&RQQHFWWKHVLSKRQWRDGUDLQWUDSPDNLQJVXUHWKHVORSHLVFRQWLQXRXV
Avoid horizontal stretches.
'RQRWOLIWWKHERLOHUH[HUWLQJSUHVVXUHRQWKHSODVWLFSDUWVOLNHWKHVLSKRQDQGWKHÀXHWXUUHW
Tighten the boiler water connections with care (maximum tightening torque 30 Nm).
%HIRUHVWDUWLQJXSWKHERLOHU¿OOWKHZDWHUVLSKRQWRSUHYHQWWKHIXPHVIURPGLႇXVLQJLQWKHURRP
9.1 BOILER DIMENSIONS AND GAS WATER CONNECTIONS
7KHGLPHQVLRQVRIWKHERLOHUDQGWKHUHODWLYHLQVWDOODWLRQSRVLWLRQVRIWKHZDWHUFRQQHFWLRQVDUHVKRZQLQWKHDQQH["SECTION"
C at the end of the manual.
A Condensate drain point D GAS inlet
B +HDWLQJÀRZ E &ROGGRPHVWLFZDWHULQOHW6\VWHP¿OOLQJWDS
C '+:RXWOHW*´%RLOHUKHDWLQJÀRZ*´ F Heating return