Heat
User Guide
Gas Fired Wall Mounted Condensing Boiler
09
United Kingdom
613 - 616 - 619 - 625 - 630
Please keep these instructions in a safe place.
If you move house please hand them over to the next occupier.

Other manuals for Baxi Heat 625

Questions and Answers

  • D
    Donna SimonAug 8, 2025
    How to troubleshoot temperature protection issues in my Baxi Heat 625 Boiler?
    • B
      Brooke RojasAug 8, 2025
      If your Baxi Boiler is experiencing temperature protection issues, it could be due to several reasons: * The maximum flow temperature may have been exceeded. * The flow temperature rise rate might be too high. * There could be an excessive difference between the flow and return temperatures. To resolve this: * Check the system circulation and pump operation. * Verify the demands for boiler operation. * Check the temperature setting. * Inspect the temperature sensors in the boiler.
  • B
    Brittany HarperAug 13, 2025
    What to do if my Baxi Heat 625 Boiler displays a communication fault?
    • N
      nielsencherylAug 13, 2025
      If your Baxi Boiler shows a communication fault, the cause may be a bad connection or wiring fault, or an internal communication fault. To address this: * Check the wiring and connections between the boiler and the User Interaction Controller, and also within the box. * If necessary, replace the combustion control unit.
  • B
    bmarksAug 18, 2025
    Why is my Baxi Boiler losing flame?
    • T
      Terri McdonaldAug 18, 2025
      If your Baxi Boiler is experiencing flame loss, it means no flame was detected during operation. Here’s what you can do: * First, check that the gas supply is turned on and available, especially if you're using a pre-payment meter. * Next, check the condition of the flue.
  • D
    Darrell MccormickAug 25, 2025
    What does shutdown input mean on my Baxi Heat 625 Boiler?
    • M
      Michael BoothAug 25, 2025
      If your Baxi Boiler is showing a shutdown input error, it means the BL terminals on the User Interaction Controller are open circuit. Here’s how to troubleshoot: * If a condensate pump is wired to these terminals, check its operation. * Check the wiring to the BL terminals, ensuring the link is present or the connections to the external device are correct.
  • V
    Vincent HarrisAug 28, 2025
    What causes a parameter fault in a Baxi Heat 625 Boiler?
    • J
      James ButlerAug 28, 2025
      If your Baxi Boiler is showing a parameter fault, it could be due to a parameter error, a faulty PU, a configuration error, or a PCB fault. The suggested solution is to replace the combustion control unit.
  • C
    Charles HansenSep 2, 2025
    What does a miscellaneous error mean on my Baxi Heat 625?
    • N
      Nicholas OwensSep 2, 2025
      If your Baxi Boiler has a miscellaneous error, it indicates an internal fault in the combustion control unit. The suggested solution is to replace the combustion control unit.

Summary

The Benchmark Scheme

Introduction

General Information

Provides essential information about the boiler's intended use and manufacturer liability.

Extent of Liabilities

Manufacturers Liability

Outlines manufacturer's responsibility and conditions under which liability is excluded.

Installers Responsibility

Details the installer's duties concerning installation and user handover.

Users Responsibility

Explains user's obligations for correct operation, maintenance, and warranty.

Safety

General Safety Instructions

Provides critical safety advice, including what to do if gas is smelled and warnings about hot surfaces.

Benchmark Commissioning Checklist

Explains the importance and process of the Benchmark Checklist for warranty and compliance.

Technical Specifications

Description of the Product

Operation

Operation Checking Procedure & Basic Fault Identification

Provides a step-by-step guide to check if the boiler is operating correctly and identify basic faults.

Settings

Maintenance

Troubleshooting

Fault Warning & Lock-out Codes

Explains status light codes and how to reset faults.

Fault Finding

Presents a table of common problems and their possible causes for troubleshooting.

Warranty

Warranty Maintenance and Support

Annual Service Requirements

Details the necessity and timing of annual servicing for warranty validation.

Customer Support and Problem Resolution

Provides contact information and process for experiencing issues with the boiler.

Baxi Heat 625 Specifications

General IconGeneral
MountingWall-mounted
Output Power25 kW
CH Output25 kW
DHW Output25 kW
ERP RatingA
Fuel TypeNatural Gas
Flow Rate10.2 L/min
Heating Flow Temperature Range30-80 °C
DHW Flow Rate at 35°C Rise10.2 L/min
Gas Supply Pressure20 mbar
TypeCombi Boiler
Dimensions (HxWxD)700 x 400 x 280 mm