Baxi MULTI-HEAT - Starting up the Boiler

Baxi MULTI-HEAT
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Factory setting (P05) = 5 seconds
The settings can be changed by pressing on + or minus on REG (R).
By means of the operation form button (C), the desired setting can be saved, and it is
possible to "step" further in the menu.
Step through the program with the menu button (B).
NB: You must "step" at least one level further before you "save". (If you do not do this,
the latest figure will not be saved)
Save data New data are saved by closing down and pressing the ON/OFF button (E).
Regret If, nevertheless, you do not want to save the new input data which have been entered,
you can regret by pressing the alarm/reset button (F).
Letters in brackets () see fig. 1.3
Page 9
(D) Ebullition
thermostat
If the boiler temperature reaches up to approx. 100°C the ebullition thermostat will
switch off the boiler, and the display will show (A-2). In order to reconnect, unscrew
the protective cap and press in the pin which has sprung. The alarm is then re-set by
pressing in (F).
(P) Pump The circulation pump for the heating plant can be ignited (light diode = ON) or switched
off.
1.4 Starting up the boiler
Prior to starting up the boiler, it is necessary to ensure that there is sufficient water in the system.